MULTI-UNIT SYSTEM FOR LARGE VOLUMES
Multiple T-M32's can be combined for a Multi-Unit system, along with the Multiple Unit
Controller and Remote Controller (Parts TM-MC01 and TM-RE30). Each set of controllers (one
TM-MC01 and one TM-RE30) can control from 2 units to 20 units for commercial or residential
applications. For a 20-unit system, the computer can modulate between the usages of 24,000
BTU/h to 4.8 Million BTU/h.
MOBIUS
Water Heater
Model T-M32
Cold IN
An individual cut-off switch if hard-wired is recommended for each unit in a multi-unit system for
the purpose of maintenance.
Multi-Unit System Connection Diagram
Multi-Unit Controller (TM-MC01) and Temperature Remote Controller (TM-RE30 or TM-RE10)
wiring:
Unit 1
Connectors
Connectors
Left bank of
Left bank of
Dipswitches
Dipswitches
Communication cable
The dark squares indicate the direction the dipswitches
should be set to.
This is the connection diagram between T-M32 and
TM-MC01 for 2 to 20 water heaters. As shown is a
sample for 3 T-M32s.
・Make sure the "7-seg LED" of all the units'
computer boards display the unit #. The TM-
MC01 automatically allocates the unit # (1-20) to
each water heater that is part of the Multi-unit
system.
Unit2
Connectors
Connectors
Left bank of
Left bank of
Dipswitches
Dipswitches
- 28 -
Unit3
Connectors
Left bank of
Dipswitches
T M- R E 3 0
o r
T M- R E 1 0
T M - M C 0 1
Terminals for
Water
heaters
TM-MC01
Hot Out