Takagi Mobius Water Heater T-M32 ASME Installation Manual And Owner's Manual page 43

On-demand water heater
Hide thumbs Also See for Mobius Water Heater T-M32 ASME:
Table of Contents

Advertisement

Dual-purpose hot water heating (Domestic and Space Heating):
Thermostatic Mixing Valve
Heating Coil
(used with air-handler)
**Maximum allowable distance of
50-Ft. from water heater and
heating panel
* Size the pump to provide at about 2 GPM through the system at 15 Ft of Head plus applications
and piping head losses. 2 GPM will allow the system to operate at its optimal performance.
* If the application requires a higher re-circulating flow rate, make sure that the re-circulating flow
rate is no greater than 4 GPM. If the flow rate is too high, the system could be damaged by
erosion.
Priority Control Devices such as a flow switch, an Aquastat or other electronic controller can be used to
prioritize the domestic water system over the heating system.
Warning: Follow all local codes, or in the absence of local codes, follow the most recent edition of the
National Standard Code, ANSI Z21. 10.3.
Warning: This illustration is a concept design only. The reference to the 1/8
the State of Massachusetts. There are a wide variety of variations to the application of controls and
equipment presented. Designers must add all necessary safety and auxiliary equipment to conform to
code requirements and design practice. For more details, contact the Takagi Technical Department at
(888) 882-5244
Diagramatic Layout of Radiant Heating and
Domestic Water Heater Per Mass. Code
Apply Correct
Shut-Off
Thermal
Valve
Expansion
Tank-Size Per
Application
Pressure
Gauge
Tempered
Water To
House
Thermometer
Thermometer
T
Check
Valves
Shut-Off
Valves
Pump (Must Be Sized Properly
With Each Application). Pump
Shall Run 60 Seconds Every 6
Hours
An approved Pressure Only
Relief Valve, Tie to Location
Cold Inlet
approved by Local Codes and
Must Meet BTU Rating of Takagi
Check Valve Will
Model Used
Have 1/8" Hole in
Check, As Per
Mass. Code
Atmospheric
Vacuum Breaker
P
Takagi
Hot
Cold
Water
Water
Outlet
Inlet
Drain
Plug
Check Valve
T-Handle Gas
Shut-Off Valve
- 43 -
4" Gas Exhaust Vent (Discharge
Must Comply with Local and
State Codes). Can Not Be
Common Vented with Other
Appliances
Gas
Inlet
Water
Filter
120 VAC Switch or Outlet
Unions
th
hole in check is only for

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mobius water heater t-m32

Table of Contents