General Troubleshooting - Takagi Mobius Water Heater T-M32 ASME Installation Manual And Owner's Manual

On-demand water heater
Hide thumbs Also See for Mobius Water Heater T-M32 ASME:
Table of Contents

Advertisement

GENERAL TROUBLESHOOTING

~ TEMPERATURE and AMOUNT OF HOT WATER ~
PROBLEM
It takes long time to get hot water at
the fixtures.
The water is not hot enough.
The water is too hot.
The hot water is not available when
a fixture is opened.
The hot water gets cold and stays
cold.
Fluctuation in hot water temperature. • Is the filter on cold water inlet clean? (p. 35)
POSSIBLE SOLUTIONS
• The time it takes to deliver hot water from the T-
M32 to your fixtures depends on the length of
piping between the two. The longer the distance or
the bigger the pipes, the longer it will take to get hot
water.
• If you would like to receive hot water to your fixtures
quicker, you may want to consider a hot water
recirculation system. (p. 42)
• Compare the flow and temperature. See the chart
on p. 51.
• Check cross plumbing between cold water lines
and hot water lines.
• Is the gas supply valve fully open? (p. 30)
• Is the gas line sized properly? (p. 16)
• Is the gas supply pressure enough? (p. 15)
• Is the set temperature set too low? (p. 31,34)
• Is the set temperature set too high? (p. 31,34)
• Make sure the unit has 120V 60Hz power supply.
• If you are using the remote controller, is the power
button turned on? (p. 31)
• Is the gas supply valve fully open? (p. 30)
• Is the water supply valve fully open? (p. 30)
• Is the filter on cold water inlet clean? (p. 35)
• Is the hot water fixture sufficiently open to draw at
least 0.5 GPM through the water heater? (p. 31)
• Is the unit frozen?
• Is there enough gas in the tank? (for LP)
• Is the flow rate enough to keep the T-M32 running?
(p. 31)
• If there is a recirculation system installed, does the
recirculation line have enough check valves?
• Is the gas supply valve fully open? (p. 30)
• Is the filter on cold water inlet clean? (p. 35)
• Are the fixtures clean of debris and obstructions?
• Is the gas line sized properly? (p. 16)
• Is the supply gas pressure enough? (p. 15)
• Check for cross connection between cold water
lines and hot water lines.
- 36 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mobius water heater t-m32

Table of Contents