Horizontal Installation Diagram
Vertical Condensation Drain
(Install according to local codes)
TK-BF01 Backflow preventor
(Recommended for freezing
weather conditions: 36°F and
below)
Vertical Installation Diagram
Vertical Condensation Drain
(Install according to local codes)
• Regarding the clearance from the terminator to the air inlet or opening, refer to the next
page.
• Install a condensation drain in the venting.
• Follow the vent system to vent manufacturer's instruction and local code.
• Do not common vent or connect any vent from other appliances to the T-M32 vent.
• Use 4" category III approved or Special BH, single or double wall stainless steel vent
pipe.
Roof
TK-BF01 Backflow preventor
(Recommended for freezing
weather conditions: 36°F and
below)
- 13 -
Wall
Sidewall Vent
Terminator
Rain Cap
Roof Flashing