Maintenance And Service - Takagi Mobius Water Heater T-M32 ASME Installation Manual And Owner's Manual

On-demand water heater
Hide thumbs Also See for Mobius Water Heater T-M32 ASME:
Table of Contents

Advertisement

WARNING: Turn off the electrical power supply and close the manual gas
control valve and the manual water control valve before servicing.
• Clean the cold-water inlet filter. (Refer to diagram below)
• Be sure that all openings for combustion and ventilation air are not blocked.
• Check that the exhaust vent pipe is not blocked.
• Check the gas pressure.
• Keep the area around the water heater clear. Remove any combustible materials, gasoline or
any flammable vapors and liquids.
TAKAGI recommends having the unit checked once a year or as necessary by a licensed
technician. If repairs are needed, any repairs should be done by a licensed technician.
1. Close the manual gas shut off valve.
2. Turn off power to the unit, and then turn on again.
3. Wait 30 seconds, and then turn off power to the
unit, yet again.
4. Close the water shut off valve.
5. Open all hot water taps in the house. When the
residual water flow has ceased, close all hot
water taps.
6. Have a bucket or pan to catch the water from the
unit's drain plugs. Unscrew the drain plugs to
drain all the water out of the unit.
7. Wait a few minutes to ensure all water has
completely drained from unit.
8. Clean the filter: Check the water filter located
within the cold inlet. With a tiny brush, clean the
water filter of any debris which may have
accumulated and reinsert the filter back into the
cold water inlet.
9. Securely screw the drain plugs back into place.
Hand- tighten only.

MAINTENANCE AND SERVICE

UNIT DRAINING and FILTER CLEANING
Drain Plug
- 35 -
Water Valve
Gas Valve
Drain Plug
with Filter

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mobius water heater t-m32

Table of Contents