Oce ColorWave 300 User Manual page 255

Operating information
Hide thumbs Also See for ColorWave 300:
Table of Contents

Advertisement

Use the 'Tone scale area check' print to test the scanner
On request of the helpdesk the 'Tone scale area check' print can be used to indicate
scanner problems. Use the 'Scan to USB' option.
1. Feed the 'Tone scale area check'print face up, landscape and centered on the original
feeding table.
2. Select 'Scan' on the user panel.
3. Open the 'Scan' tab with the confirmation button above the scroll wheel.
4. Use the scroll wheel to select or create a scan template with the following settings:
'Destination': 'USB stick'
'File type': 'Color', 'JPEG'
'Resolution (dpi)': 400
'Original': 'Map',
5.5.'Insert USB device'.
6. Press the start button.
7. After the scan to USB is finished, remove the USB mass storage device and send the
(scanned) file to the helpdesk.
'Tone scale area check' print
Chapter 6 - Ensure the best output quality