Venting Information - HearthStone Sterling-Ht 8532 Owner's Manual & Installation Manual

Gas-fired direct vent heater select collection
Table of Contents

Advertisement

Hearthstone Quality Home Heating Products, Inc
V
I
ENTING
NFORMATION
The Sterling is approved for installation only
with the following venting manuafcturers
products.
Simpson Dura-vent Direct Vent GS
AmeriVent Direct
Secure Vent systems
Selkirk Direct-Temp™
EXCELDirect
W
ARNING
This appliance must not be connected to a chimney
flue serving a separate solid-fuel burning appliance.
The Sterling can be vented two ways:
A) Straight out the back exit, using 5"x8" pipe.
B) Top exit, using kit #95-60320. If you want to
run your vent vertically, you must buy this
vertical vent kit which will convert the venting
pipe to 4"x6". The restrictor will be part of this
kit. No restrictor is needed for a horizontal
exit.
When referring to the rest of this section ensure
which way your unit is being vented.
Note:
If the unit is vented vertically, 4"x6" pipe
must be used.
If using Top Exit Kit, a 24" section of pipe
must be used directly off of stove.
A
V
PPROVED
ENTING
C
OMPONENTS
Component Description
0
90
Elbow
0
45
Elbow
6" Straight
9" Straight
12" Straight
24" Straight
36" Straight
48" Straight
11"-14
Adjustable Pipe Length
5/8"
Horizontal Vent Cap
S
YSTEM
Termination
Cap
Vertical Vent Cap
Snorkel 36"
Vinyl Siding Standoff 4 x 6
Round Ceiling Support Wall
Thimble Covers
Wall thimble
If the vent air intake system, for any reason, is
disassembled, it must be reinstalled per the
instructions provided for in the initial installation.
Allowable Venting Configuration Graphs
When determining the venting configuration, you
must consider the position of the termination cap.
There are 5 possible categories.
A)
Fireplace & Existing chimney
installation
B)
Horizontal termination for 5"x8" pipe
C)
Horizontal termination for 4"x6" pipe
D)
Vertical termination straight or 2 45
elbows (4"x6" pipe only)
E)
Vertical termination, 1 or 2 90
(4"x6" pipe only)
Every venting configuration must fall into one of
these categories.
The vent/air intake termination clearances above the
high side of an angled roof as follows:
Horizontal
Overhang
Vertical Wall
9
Termination Clearances
STERLING-Ht Model 8532
5/8"
O
elbows
Roof Pitch
Feet
Meters
Flat to 6/12
1
0.3
7/12 to 9/12
2
0.6
10/12 to 12/12
4
1.2
13/12 to 16/12
6
1.8
17/12 to 21/12
8
2.4
The termination cap must not
be recessed into a wall or
ceiling.