Specifications - HearthStone Sterling-Ht 8532 Owner's Manual & Installation Manual

Gas-fired direct vent heater select collection
Table of Contents

Advertisement

Hearthstone Quality Home Heating Products, Inc
2" (51mm)
Parallel Installations
3" (76mm)
Corner Installations
C
C
LEARANCE TO
OMBUSTIBLES

SPECIFICATIONS:

L
: D
V
ISTED
IRECT
ENT
Model: 8532-Sterling Ht DV
Testing Agency:
Intertek Testing Services NA, Inc. (ITS)
Tested to: ANSI Z21.88-1998•CSA 2.33-M98 CAN/CGA 2.17
* You may keep your orifices the same if you wish to burn at the lower 33,000 btus with the top exit kit.
Venting Exit Type
Gas Type
Input rating (Btu/hr) 0-2000ft
Maximum output (Btu/hr) 0-2000ft
Minimum input rating (Btu/hr)
Orifice size DMS 0-2000ft
Man. pressure- HI setting (in.w.c./kPa)
Man. pressure- LO setting (in.w.c./kPa)
Minimum inlet pressure (in.w.c./kPa.)
Maximum inlet pressure (in.w.c.)
4" (102mm)
3" (76mm)
G
H
AS
EATER
2" (51mm)
1" (26mm)
14" (355mm)
Floor
Mantel Installations
Rear Exit – 5"x8" Pipe
NG
LP
33,000
33,000
26,600
27,400
13,600
11,900
43,52
55,63
3.5/0.87
10.0/2.48
1.2/0.3
3.3/0.8
5.0/1.24
11.0/2.88
7.0
13
7
STERLING-Ht Model 8532
18" (458mm)
2" (51mm)
*Top Exit – 4"x6" Pipe
NG
LP
38,000
38,000
30,200
31,300
13,900
11,600
38,51
53,63
3.5/0.87
10.0/2.48
1.2/0.3
3.3/0.8
5.0/1.24
11.0/2.88
7
13

Advertisement