MODEL NAME: STERLING-Ht DIRECT VENT GAS FIREPLACE HEATER
LISTED: VENTED GAS FIREPLACE HEATER
TESTED TO: ANSI Z21.88-2002 CSA 2.33-M02, CAN/CGA-2.17-M91
CAUTION: DO NO T OPERATE WITH GLASS REMOVED, CRACKED, OR BROKEN.
Replacement on the panel should be done by a licensed or qualified service person.
CAUTIONNER: N'op re l'appareil avec le verra enl ve, craque ou casse. Le
è
remplacement du panneau devrait tre fait par une personne de service qualifi ou aut oris .
FUEL TYPE:
INPUT RATING (Btu/hr) 0-2000 ft
INPUT RATING (Btu/hr) 2000-4500 ft
ORIFICE SIZE (DMS) 0-2000 ft
ORIFICE SIZE (DMS) 2000-4500 ft
MANIFOLD PRESSURE - LO (in. W.c./kpa)
MANIFOLD PRESSURE - HI (in. W.c./kpa)
MINIMUM INLET PRESSURE (in.w.c./kpa)
MINIMUM INPUT RATING (btu/hr) 0/2000 ft
MAXIMUM OUTPUT (btu/hr) 0-2000 ft
MINIMUM CLEARANCES TO COMBUSTIBLES
EDGE OF TOP TO: CEILING / MANTLE (17")
BACK OF STOVE TO: BACKWALL
EDGE OF SIDE TO: SIDEWALL
Several Optional kits are available through HearthStone or your local HearthStone dealer. A blower assembly
may be used
(kit# 95-57320)
(kit #90-56912 & kit #90-56914) are optional as well.
This appliance is only for use with the type of gas indicated on this rating plate and may be installed in an aftermarket,
permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. This
appliance is not convertible for use with other gases, unless a certified kit is used. If the vent air intake system is
disassembled for any reason, reinstall per the instructions provided with the initial instructions. This vented gas fireplace
heater is not for use with air filters. This appliance must be properly connected to a venting system in accordance with the
manufacturer's installation instructions.
2004
2005
2006
DO NOT REMOVE OR COVER THIS LABEL
R
ATING
è
ê
LP
NG
5" x 8" VENTING
33,000
33,000
31,500
31,900
43, 52
55, 63
44, 53
56, 64
1.2/0.3
3.3/0.8
3.5/0.87
10.0/2.48
5.0/1.24
11.0/2.88
13,600
11,900
26,600
27,400
14" / 356mm
2" / 50 mm
4" / 100 mm
, spark screen (kit# 95-69320), top exit(kit# 95-60320), and two different remote controls
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL.
MANUFACTURED BY: HearthStone, MORRISVILLE, VERMONT 05661
Date of Manufacture
Jan
Feb
Mar
Apr
STERLING Ht Gas-Fired Direct Vent heater
L
ABEL
CE RT IF IED FOR CANA DA/HO MOLOGUE P OUR L E CANADA
ALSO F OR MO BILE HOME I NSTAL LATION
This appliance must be inst alled in ac cordance with the local
codes, if any, if not; follow the National Fuel Gas Code, ANSI
Z223.1 or Canadian Inst allation Codes, CAN/CGA B149.
é
é
l'appareil selon les codes ou ré
NG
LP
glements locaux, ou, en l'a bsence de tels réglements, selon les
4" x 6" VENTING
Codes d' installation CAN/CGA-B149.)
38,000
38,000
37,600
36,900
WARNING: Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage. Ref er t o the
53, 63
38, 51
owner's information manual provided with this appliance. For
54, 64
39, 52
assistanc e or additional information consult a qualified inst aller,
3.3/0.8
1.2/0.3
service agency or the gas supplier.
3.5/0.87
10.0/2.48
L'installation inconvenante, ajustement, modification, service ou
entretien peut causer le dommages de propriété ou blessure.
11.0/2.88
5.0/1.24
Référer au manuel d'information de propriétaire fourni cet appareil.
11,600
13,900
Pour l' assistance ou information supplémentaire consulte un
31,300
30,200
qualifiée installeur, agence de service ou le fournisseur de ga z.)
ELECTRICAL RATING:
115 VOLTS @ 60Hz, LESS THAN 2.0A
May
Jun
Jul
Aug
MADE IN USA