Venting Information; Approved Systems - HearthStone Stowe 8324 Owner's Manual

Gas-fired direct vent heater
Table of Contents

Advertisement

Hearthstone Quality Home Heating Products, Inc
V
I
ENTING
NFORMATION
V
C
ENTING
OMPONENTS
Starter collar is installed by Hearthstone.
Use the following instructions along with the pipe
manufacturer's
instructions
installation. Do not mix vent components from
different manufacturers within the same venting
system.
A
V
M
PPROVED
ENTING
The Stowe Direct Vent (8324) is approved for
installation only with the venting components
provided by manufactures listed on this page.
Simpson Dura-Vent, Inc.
P.O. Box 1510
Vacaville, CA 95696-1510
American Metal Products (AmeriVent)
8601 Hacks Cross Rd.
Olive Branch, MS 38654
Selkirk Corporation
1301 W. President George Bush Hwy, Suite 330
Richardson, TX 75080-1139
Security Chimneys International Ltd (Secure Vent)
2125 Monterey, Laval, Quebec
Canada, H7L 3T6
ICC, Inc.
400 J-F Kennedy, St. Jerome, Quebec
Canada, J7Y 4B7
Metal-Fab, Inc.
P.O. Box 1138
Wichita, Kansas 67201
V
T
ENTING
ERMINATIONS
The Stowe cannot be vented jointly with any other
solid fuel or gas appliance. It must be vented directly
to the outside of the building using a proper
termination
as
listed
determining the venting configuration for your stove,
select the vent system that will best accommodate
your installation.
CAUTION:
ENSURE
TERMINATION
CAP
OBSERVED PER THIS OWNER'S MANUAL.
CAUTION: ENSURE THERE IS NO WIRING OR
PLUMBING IN THE CHOSEN LOCATION.
CAUTION:
DO
TERMINALS INTO A WALL OR SIDING.
to
complete
ANUFACTURERS
800-835-4429
800-423-4270
800-992-8368
450-973-9999
450-565-6336
316-943-2351
in
this
manual.
After
ALL
STOVE
CLEARANCES
NOT
RECESS
VENTING
A
V
PPROVED
WARNING:
PARTICULARLY COLD CLIMATES IT MAY BE
NECESSARY TO HEAT YOUR VENT SYSTEM
WITH THE PILOT PRIOR TO IGNITION OF THE
MAIN BURNER. IN THESE INSTANCES IT IS
the
RECOMMENDED THAT YOU LEAVE THE PILOT
RUNNING FOR 5 MINUTES PRIOR TO IGNITING
THE MAIN BURNER. THIS WILL ALLOW FOR
PROPER START UP AND IGNITION OF ALL
PORTS ON THE BURNER.
There are three types of venting configurations
approved for use with this appliance:
Vertical Venting/Vertical Termination
Vertical Venting/Horizontal Termination
Horizontal Venting/ Snorkel Termination
Pipe Clearances to combustibles:
1" to vertical runs
1" below and to the side of horizontal runs
2" from the top of horizontal runs
Vertical Venting and Termination
The Stowe 8324 is approved for venting vertically
through a roof or ceiling. When installing a vertical
vent and/or vertical terminations you must adhere to
the following requirements:
When terminating vertically you must have at
least 10' of vertical pipe.
Always maintain a minimum of 1" clearance from
all sides of the vent system to any combustible
material (2" from top).
A listed fire stop is required at any floor
penetration. The opening must be framed in
according
instructions.
Steep roofs, nearby trees, or predominantly
strong windy conditions can promote poor draft
or down draft conditions. In this event, an
increase to the height of the vent may improve
performance.
A maximum of two 90⁰ or four 45⁰ elbows may
be used in vertical terminations. (This includes
the one 45⁰ elbow off the stove outlet)
Whenever possible use 45⁰ elbows instead of
90⁰ elbows as they offer less restriction to the
AND
ARE
flue gases.
Vertical terminations may require additional
restriction in order to perform as intended.
Please refer to Figures 29 & 30 to adjust your
vent restrictor accordingly
STOWE Model 8324
C
ENTING
ONFIGURATIONS
IN
HIGH
WIND
AREAS
to
the
venting
manufacturer's
AND
11