4. Remove two INNER GUIDE B mounting screws, and then remove the INNER GUIDE B.
5. Release three tabs, and then remove the APS.
Inner guide B
APS

FEED ROLLER B

1. Remove the TX SIDE COVER R and F.
2. Remove the ADF MOTOR.
3. Remove the Scanner Cover Assembly.
4. Remove two INNER GUIDE B mounting screws, and then remove the INNER GUIDE B.
5. Remove the APS.
6. Remove two E-rings on the right and left of the FEED ROLLER B, and then remove the PULLEY 17 and
bearings. Also, remove the two GUIDE SPRINGS.
Feed roller B
Pulley 17
Bearing
Inner guide D
Guide spring
Inner guide C
Bearing
Guide spring
7. Remove the INNER GUIDE C.
8. Remove the INNER GUIDE D.
9. Remove the FEED ROLLER B.