5. Release the tab of the harness door under the machine, and then remove the harness door.
6. Put the machine on the second cassette.
7. Pass the harness and the ground wire of the second cassette through the harness door.
Connect the harness to the connector (P17) on the Main control PCB.
8. Re-attach the shield plate using four mounting screws.
Note: You should attach the ground wire at the lower left corner of the shield plate using the screw, as
shown in the illustration.
6-23