Alcatel-Lucent OMNIACCESS 6000 Installation Manual page 40

Wireless lan switch
Hide thumbs Also See for OMNIACCESS 6000:
Table of Contents

Advertisement

OmniAccess 6000: Installation Guide
Indicator LEDs
3
LED Name
Over
Temp.
Protection
DC Okay
AC Okay
LED Name
Over
Temp.
Protection
DC Okay
AC Okay
4
Air Intake Vent
This air intake vent helps the internal fan cool the power supply during
operation. To prevent blockage, keep all material at least 10 cm (4 inches) from
the vent.
5
Power Cord Retaining Clip (optional 400 W
This clip fits over the power cord once the plug has been inserted into the
power input socket. It helps prevent the power cord from being pulled out
accidentally.
26
Part 031639-00
T
5-1 200 W Power Supply LEDs
ABLE
Position
State
Top
Off
Amber
Middle
Green
Off
Bottom
Green
Off
T
5-2 400 W Power Supply LEDs
ABLE
Position
State
Top
Off
Red
Middle
Green
Red
Bottom
Green
Red
Description
Power supply temperature is okay.
Power supply fan has failed or
temperature is too high.
DC power output is okay.
DC power output is not within
tolerance.
AC power input is okay.
AC power input is not within tolerance.
Description
Power supply temperature is okay.
Power supply fan has failed or
temperature is too high.
DC power output is okay.
DC power output is not within
tolerance.
AC power input is okay.
AC power input is not within tolerance.
OWA-6000-PS400