Problem
The display shows F111.
The lamp does not oper-
ate.
If you cannot find a solution to the problem yourself, contact your dealer or the service
centre.
The necessary data for the service centre is on the rating plate. The rating plate is on the
front frame of the appliance cavity.
We recommend that you write the data here:
Model (MOD.)
Product number (PNC)
Serial number (S.N.)

INSTALLATION

WARNING!
Refer to "Safety information" chapter.
The built-in unit must meet the stability requirements of DIN 68930.
The oven is designed to be connected to 230 - 240V ~ (50Hz) electricity supply.
The oven has an easily accessible terminal block which is marked as follows:
Letter L - Live terminal
Letter N - Neutral terminal
- Earth terminal
CAUTION!
This oven must be earthed!
The cable used to connect the oven to the electrical supply must comply to the specifica-
tions given below.
For UK use only
Connection via
Cooker Control Circuit
It is necessary that you install a double pole switch between the oven and the electricity
supply (mains), with a minimum gap of 3 mm between the switch contacts and of a type
suitable for the required load in compliance with the current regulations.
The switch must not break the yellow and green earth cable at any point.
Possible cause
The CT Sensor plug is not correctly
installed into the socket.
The lamp is defective.
Min. size Cable/flex
2,5 mm²
Put the plug of core temperature
sensor as far as possible into the
socket.
Replace the lamp.
.........................................
.........................................
.........................................
Cable/flex type
PVC / PVC twin and
earth
45
Installation
Remedy
Fuse
min: 15 A
max: 20 A