Disabling Priming with an Automation System

When the pump is connected to an automation control system, (IntelliTouch, EasyTouch or
SunTouch), the priming feature on the pump cannot be disabled by the external
automation control system only.
If priming is enabled on start-up, the pump responds to its internal settings before
responding to commands from an automation control system. If the pump is connected to an
automation control system and priming is not desired, disable the priming feature on both
the pump and the automation control system.
To disable priming with an automation control system:
1. Disable the priming feature on the automation control system at the load center or using
an IntelliTouch or EasyTouch remote. (Refer to the automation control system user's guide
for additional information).
2. Temporarily disconnect the RS-485 communication cable.
3. Open the LCD screen lid to disable priming on the pump. Press the MENU button, use the
arrow buttons to scroll and select "Priming", then select "Disabled" (the factory default is
set to "Enabled"). Press Escape to exit the menu.
4. Once priming is disabled, reinstall the RS-485 communication cable.
1. Disable priming on automation control system.
3. Disable priming on pump.
IntelliFloXF
and IntelliProXF
2. Disconnect the RS-485 communication cable.
4. Reinstall the RS-485 communication cable.