12
MENU
SETTINGS
Set Maximum Speed (RPM)
The maximum speed can be set from 1900 RPM to 3450 RPM (default is 3450). Use this setting
is to set the maximum running speed of the pump. When the pump is set to Priming "Enabled",
the pump will ramp up to and run at this speed to prime. A service professional must set the
Maximum Speed of the pump to not exceed the maximum fl ow rate of the system on which it
will operate.
CAUTION: The Maximum Flow rate setting should be set so the system never operates at or
above 25" of Hg vacuum.
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrows to scroll to "Set Max Speed".
5. Press Select to change. The cursor will appear in the fi rst number column (ones).
6. Press Up or Down arrows to change the maximum speed setting from 1900 to 3450 RPM.
7. Press Enter. Press Escape to exit. To cancel, press the Escape to exit without saving.
Set Minimum Speed (RPM)
The minimum pump speed can be set from 450 RPM to 1700 RPM. The default setting is
450 RPM.
1. Check that the green power LED is on.
2. Press Menu.
3. Press Select to select "Settings".
4. Use the Up or Down arrows to scroll to "Set Min Speed".
5. Press Select to change the setting. The cursor will appear in the fi rst number column.
6. Press the Up or Down arrows to change the minimum speed setting from 450 to 1700 RPM.
7. Press Enter to save. To cancel, press Escape to exit edit mode without saving.
8. Press Escape to exit.
IntelliFloXF
and IntelliProXF
Pump Menu: Settings