Connecting to an Automation System

External Control with IntelliComm

Use the RS-485 communications cable to remotely control
the pump from an IntelliComm Communication Center. The
IntelliComm provides four (4) pairs of input terminal
connections. These inputs are actuated by either 15 - 240
VAC or 15 - 100 VDC. Use the device inputs, to control the
programmed pump speeds.
Note: For the pump to accept commands from
IntelliComm, the pump must be in the
"Running Schedules" mode (LED above Start/Stop
button is on). If more than one input is active, the
highest number will be communicated to the pump. The
IntelliComm will always communicate to pump using
ADDRESS #1.
Program Number Priority
If programs 1 and 2 are activated, program 2 will run, regardless of the assigned speed (RPM).
The higher program number will always take priority.
Terminal
Number
1-2
3-4
5-6
7-8
9-10
11
12
Refer back to page 16 for instructions for setting up Programs in the External Control menu.
External Control is for programming speeds that will run when the IntelliComm power center
controller sends it a command. For example, Terminal 3 and 4 in IntelliComm will correspond
to External Control Program #1. (5 and 6 to Ext Ctrl #2). Use the External Control feature to
program the IntelliComm power center.
®
Communication Center
Wiring Terminal Descriptions for Intellicomm
Terminal
Voltage
Name
Power Supply
100 - 240 VAC
15 -240 VAC
Program 1
or
15 - 100 VDC
15 -240 VAC
Program 2
or
15 - 100 VDC
15 -240 VAC
Program 3
or
15 - 100 VDC
15 -240 VAC
Program 4
or
15 - 100 VDC
RS-485
-5 to +5 VDC
+ Data: Yellow
- Data: Green
Ground
IntelliFloXF
and IntelliProXF
IntelliComm
Communication Center
Maximum
Phase Type
Current
100 mA
1 Input
1 mA
1 Input
1 mA
1 Input
1 Input
1 mA
1 mA
1 Input
1 Output
5 mA
Variable Speed Pump Installation and User's Guide
21
®
Frequency
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
N/A