Troubleshooting

Alerts and Warnings

The pump displays all alarms and warnings on the control panel display. When an alarm or
warning condition exists, the corresponding light will be lit on the display. All control panel buttons
are disabled until the alarm or warning is acknowledged with the Enter button.
Press the Reset button to clear the alarm once the fault condition has been resolved.
Note: The pump will not start if the impeller is rotating.
Power Out Failure
The incoming supply voltage is less than 170 VAC. The drive faults to protect itself from over
current. The drive contains capacitors that keep it powered up long enough to save the cur-
rent run parameters. If power is restored during this process, approximately 20 seconds, the
drive will not restart until completed.
Priming Error
If the pump is not defi ned as primed within the "Max Priming Time" it will stop and generate a
"Priming Alarm" for 10 minutes, then attempt to prime again. The "Max Priming Time" is set by
the user on the priming menu as discussed on page 18. If the pump cannot prime within fi ve
attempts it will generate a permanent alarm that must be manually reset.
Overheat Alert
If the drive temperature gets above 54.4° C (130° F) the pump will slowly reduce speed until
the over temperature condition clears.
Anti-Freezing
When active, the motor will run at the preset RPM until the drive temperature increases
above the minimum. The pump's internal antifreeze protection is disabled when connected
to an automation system. Freeze protection is provided by selecting YES at the ON WITH
FREEZE portion of the IntelliTouch's appropriate circuit function menu. To re-enable the
internal antifreeze protection, the power to the drive must be cycled off then back on.
Over Current
Indicated that the drive is overloaded or the motor has an electrical problem. The drive will
restart 20 seconds after the over current condition clears.
Over Voltage
Indicates excessive supply voltage or an external water source is causing the pump and
motor to rotate thereby generating an excessive voltage on the drives internal DC buss. The
drive will restart 20 seconds after the over voltage condition clears.
IntelliFloXF
and IntelliProXF
Always disconnect power to the pool pump at the circuit breaker and disconnect the communication
cable before servicing the pump. Failure to do so could result in death or serious injury to serviceman,
pool users or others due to electric shock. DO NOT attempt to adjust or service without consulting
your dealer or a qualifi ed pool technician. Read the entire Installation & User's Guide before attempting
to use, service, or adjust the pool fi ltering system or heater.