Operator Control Panel Menu Guide - Pentair IntelliFloXF Installation And User Manual

Variable speed ultra energy efficient pump
Hide thumbs Also See for IntelliFloXF:
Table of Contents

Advertisement

Operator Control Panel: Pump Menu Guide
MENU
SETTINGS
(Pages 10 -13)
SPEED 1-8
(Pages 14 -15)
EXT CONTROL
(Pages 16)
FEATURES
(Pages 16 -17)
PRIMING
(Pages 18 - 19)
ANTI FREEZE
(Page 20)
Press MENU button to access pump menus.
Pump Address
Set Time
Set AM/PM
Temperature Unit
Screen Contrast
Language
Set Min Speed
Set Max Speed
PASSWORD
Speed 1 (1-4)
Speed 5 (5-8)
Program 1
Program 2
Program 3
Program 4
Time Out
Quick Clean
Default: Enabled
DISABLED/ENABLED
MAX PRIMING TIME
PRIMED SENSITIVITY
PRIMING DELAY
DISABLED/ENABLED
SET SPEED
PUMP TEMPERATURE
IntelliFloXF
and IntelliProXF
(1-16) Default: ADDRESS 1
(hr:mm) Default: 12:00 AM
AM/PM
24 hr.
Fahrenheit - Default: F°
C° Celsius
(1-5) Default 3
English - Default: English
(450 RPM - 1700 RPM) - Default: 450 RPM
(1900 RPM - 3450 RPM) - Default: 3450 RPM
Disabled/Enabled - Default: Disabled
Password Time Out (1 min. - 6 hours) Default:10 minutes
Enter Password (xxxx) Default: 1234
Manual
Set Speed - Default: MANUAL
Schedule
Set Speed
Set Start Time
Set Stop Time
Egg Timer
Set Speed
Time
Disabled
Default: Disabled
Schedule
Set Speed
Set Start Time
Set Stop Time
Speed - Default: 750 RPM
Speed - Default: 1500 RPM
Speed - Default: 2350 RPM
Speed - Default: 3110 RPM
Time Out Duration (1 min. to 10 hrs.) Default: 3 hours
Set Speed (1100 -3450 RPM) Default: 3450 RPM
Time (1 min. to 10 hrs.) Default: 10 minutes
(1 min. to 30 min.) Default: 11 minutes
(1 - 100%) Default: 1%
(1 second - 10 minutes) Default: 20 seconds
Disabled / Enabled - Default: Enabled
Set Speed (750 RPM - 3450 RPM) Default 1000 RPM
40° F - 50° F (4.4° C - 10° C) Default: 40° F (4.4° C)
Variable Speed Pump Installation and User's Guide
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intelliproxf

Table of Contents