Anti Freeze - Pentair IntelliFloXF Installation And User Manual

Variable speed ultra energy efficient pump
Hide thumbs Also See for IntelliFloXF:
Table of Contents

Advertisement

20
MENU

ANTI FREEZE

The sensor for Anti Freeze is in the drive, on top of the motor. This feature allows you to set
a speed (450 RPM - 3450 RPM) that runs when the pump goes into anti freeze mode. The
temperature level that you wish anti freeze mode to start can also be set.
IMPORTANT NOTE: This feature is for protection of the pump. Do not depend on the
anti freeze feature for freeze protection of the pool. Certain situations could cause the pump
to sense a different temperature than actual air temperature. Your automation systems air
temperature sensor should be used to sense actual temperature. For example, if the pump is
located indoors, the temperature of the room does not indicate the outdoor temperature. The
pump does not sense the water temperature.
ANTI FREEZE
To access the Anti Freeze menu:
1. Check that the green power LED is on.
2. Press Menu.
3. Use the Down arrow to scroll to "AntiFreeze" and press Select.
4. The factory default for AntiFreeze is "Enabled". To disable AntiFreeze, press Select to
highlight "Enabled".
5. Press the Up arrow - "Disabled" is displayed.
6. Press Enter to save.
To program AntiFreeze when enabled:
1. To set speed and pump temperature, press the Down arrow
"Set Speed" is displayed. The factory default is 1000 RPM.
9. Press Select to change the speed. The cursor will highlight
the fi rst column (ones).
10. Use the Up or Down arrows to set speed (450 - 3450 RPM).
11. Press Enter to save the speed.
12. Press the Down arrow to Pump Temperature
temperature the pump will activate AntiFreeze, default is 40°
F/4.4° C).
13. Press Select to change the setting. The cursor will highlight
the fi rst column. Can be set
14. Press Enter to save the temperature setting.
Note: To cancel any changes, press Escape to exit
without saving.
15. Press Escape to exit.
IntelliFloXF
and IntelliProXF
Pump Menu: Anti Freeze
DISABLED/ENABLED
SET SPEED
PUMP TEMPERATURE
40° F to 50° F (4.4° C - 10° C).
Variable Speed Pump Installation and User's Guide
Disabled / Enabled - Default: Enabled
Set Speed (750 RPM - 3450 RPM) Default 1000 RPM
40° F - 50° F (4.4° C - 10° C) Default: 40° F (4.4° C)
(the
12:15p
1000
RPM
Set Speed
12:15p
°
40
F
Pump Temperature

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Intelliproxf

Table of Contents