Figure 9: Advanced Configuration Page Definitions

Admin
Administrator password. Only the administrator can configure the "Advanced Settings"
Password
page. Password field is purposely left blank for security reason after clicking update and
saved. The maximum password length is 25 characters.
g723 Rate
g723 encoding rate (6.3kbps or 5.3kbps)
Layer 3 QoS
This field defines the layer 3 QoS parameter which can be the value used for IP
Precedence or Diff-Serv or MPLS. Default value is 48.
Layer 2 QoS
This contains the value used for layer 2 VLAN tag. Default setting is
blank.
Inter Digit
Default is 4 seconds.
Timeout
Local RTP port
This parameter defines the local RTP-RTCP port pair the GXW-410x will listen and
transmit. It is the base RTP port for channel 0. When configured, channel 0 will use this
port _value for RTP and the port_value+1 for its RTCP; channel 1 will use port_value+2
for RTP and port_value+3 for its RTCP. The default value is 5004.
Use Random
This parameter, when set to Yes, will force random generation of both the local SIP and
Port
RTP ports. This is usually necessary when multiple GXW-410xs are behind the same
NAT.
Keep-alive
This parameter specifies how often the GXW-410x sends a blank UDP packet to the
interval
SIP server in order to keep the "hole" on the NAT open. Default is 20 seconds.
Use NAT IP
NAT IP address used in SIP/SDP message. Default is blank.
STUN Server
IP address or Domain name of the STUN server.
Firmware
This radio button will enable GXW-410x to download firmware or configuration file
Upgrade &
through either TFTP or HTTP.
Provisioning
Via TFTP Server This is the IP address of the configured TFTP server. If selected and it is non-zero or
not blank, the BudgeTone 200 will attempt to retrieve new configuration file or new code
image from the specified TFTP server at boot time. It will make up to 3 attempts before
timeout and then it will start the boot process using the existing code image in the Flash
memory. If a TFTP server is configured and a new code image is retrieved, the new
downloaded image will be verified and then saved into the Flash memory.
Note: Please do NOT interrupt the TFTP upgrade process (especially the power supply)
as this will damage the device. Depending on the network environment this process
can take up to 15 or 20 minutes.
Via HTTP Server The URL for the HTTP server used for firmware upgrade and configuration via HTTP.
For example, ttp://provisioning.mycompany.com:6688/Grandstream/1.0.0.26
Here ":6688" is the specific TCP port that the HTTP server is listening at, it can be
omitted if using default port 80.
Note: If Auto Upgrade is set to No, GXW-410x will only do HTTP download once at
boot up.