1. INSTALLATION
1.6.2
Fabrication of cables
Cable
Power cable
DPCY-1.5
(or equivalent)
Cable for IEC 61162
format equipment (JIS
cable TTYCS-1 or
equivalent)
Cable for AD-10
format equipment
((JIS cable TTYCS-1Q
or equivalent)
Note 1: Attach labels (supplied) to cables to differentiate between them.
Note 2: A plastic sheet is placed across the cable glands of the processor unit to keep out
foreign material. Cut out holes in the plastic where cables are to be lead in.
1-22
Sectional view, fabrication
Armor
Sheath
=
11.7 mm
Conductor
2
S = 1.5 mm
= 1.56 mm
SECTIONAL VIEW
Armor
Sheath
Shield
=
10.1 mm
Conductor
2
S = 0.75 mm
= 1.11 mm
SECTIONAL VIEW (TTYCS-1)
Armor
Sheath
Shield
=
11.3 mm
Conductor
2
S = 0.75 mm
= 1.11 mm
SECTIONAL VIEW (TTYCS-1Q)
50
Sheath
15
6
Vinyl tape
Crimp-on lug
FV1.25-5
FABRICATION
80
Shield
Cut vinyl sheath.
Expose core and fold back
shield onto cable.
Vinyl tape
15
6
Lay in clamp
where paint
was removed.
FABRICATION
50
Armor
Cut the sheath.
Lay in clamp
where paint
was removed.
50
Remove paint
by 50 mm.
45