If your machine has the Cam Timer
with black cams, then the board
mounting screws can be accessed
without removing the timer drive motor.
If your machine has white and gray
timer cams (A), then it may be
necessary to remove the timer drive
motor to access one of the fill/drain
timer mounting screws (B).
To remove the timer drive
motor (A), remove the two
phillips screws and drop the
timer drive motor out of the way.
With the drive motor removed,
you can access the fill/drain
timer mounting screws (C) and
remove them.
Service Parts Installation - Fill/Drain Timer Conversion - P/N 2103.43
__continued on next page