Water Connections - CMA Dishmachines UC65e Installation & Operation Manual

Undercounter high temperature
Table of Contents

Advertisement

Installation

Water Connections

Plumbing connections must comply with national, local plumbing and sanitary codes.
Make sure that the flexible water supply and drain hoses are not kinked.
1.
All models have a 6 ft. flexible hot water fill hose with a 3/4" GHT connector.
2.
A 1/2" or larger main incoming supply line should be installed to the dishwasher.
3.
A 1/2" or larger shut-off valve should be installed in the water supply line as close to the
dishwasher as possible for service.
4.
The hot water supply must provide a minimum of 140°F/60°C, measured at the dishwasher for
the 40°F/ 22°C rise booster.
5.
For the 70°F/39°C rise booster the hot water supply must provide a minimum of 110°F/43°C
measured at the dishwasher.