Error Messages; A.2.2 Error Messages - Fujitsu ETERNUS DX60 S2 User Manual

Disk storage system
Hide thumbs Also See for ETERNUS DX60 S2:
Table of Contents

Advertisement

Appendix A Event Notification Message List
A.2 Message List
A.2.2

Error Messages

This section describes the messages that are sent when the severity is Error for each type of
event.
Error message list
When the event type is "P"
The following messages are sent when components fail or degrade or when a temperature
error is detected.
Event type
and event
P 01SSMM00 2
P 06SSMM00 2
P 08SSMM0p 2
ETERNUS DX60 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
TrapItemID
Sensor
code
No.
0100MM00
0600MM00
0800MM0p
Copyright 2013 FUJITSU LIMITED
Upper: Message
Trap
Lower: Description
Info
-
Controller Module#m(zz xxHz) Fault
<pppppppppppp ssssssssss rrrrr>
CM is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
-
Controller Module#m(zz xxHz) BE Expander
Fault <pppppppppppp ssssssssss rrrrr>
CM EXP is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
-
Controller Module#m(zz xxHz) DI Port#p Fault
<pppppppppppp ssssssssss rrrrr>
CM DI Port is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
p: Port number (0 – 1)
m: CM number (0 – 1)
zz: Model name (FC4G, SAS, or iSCSI)
xx: CPU frequency (1.2GHz)
pp...: Component number
ss...: Serial number
rr...: Version
96
Remarks
These messages
are notified when
"Module was bro-
ken" is enabled for
Error Severity Level
in the event notifica-
tion setting.
They are not notified
during maintenance
operations.
P3AM-5512-05ENZ0