Fault Clearing
Power supply unit defective
Ê Check the LEDs of the power supply units.
If the fault LED (amber LED) on a power supply unit is on, the power supply
unit is defective.
Ê Before you replace the defective power supply unit, please contact the
Fujitsu Service Desk first.
For more information refer to
8.1.4

I/O Module (IOM)

Ê Check the IOM LEDs.
Check the SAS IN port and SAS OUT port LEDs (amber LEDs). If they are
on, try to solve the SAS connection problems indicated by them.
If the fault LED (amber LED) on a IOM is on, the IOM is defective.
Ê Before you replace the defective IOM, please contact the Fujitsu Service
Desk first.
For more information refer to
8.1.5

Temperature Sensor Error Message

Temperature too high
The temperature sensors have measured an extreme temperature (tolerable
temperature for operation see
Ê Check ServerView for service action.
8.1.6
Error LED of the Hard Disk Drive Indicates Disk
Failure
Ê Check whether the hard disk drive has been correctly installed and locked
(see
section "Removing/Installing Hard Disk Drive/Drive Dummy" on
page
42).
Ê Replace the hard disk drive. If the error LED is still on, contact the service
organization.