Advertisement

Physical I/P
VIDEO LOSS
Enabled
Priority
Sequence
Edit
VIDEO RESTORE
Enabled
Priority
Sequence
Edit
INPUT NOTES
ALTERNATE VIEW
Enabled
Channel
video input.
Physical audio input connection (jack number).
Enables automatic video loss detection for this input.
Sets the priority level for video loss sequence on this input.
(Active only when Video Loss is enabled.) Priority can be
set to a number between 0 and 255 with 0 being the highest
priority. The sequences are activated based on priority. For
example, if a sequence with priority 3 has a camera switch
to a monitor, and the sequence has locked the monitor, a
sequence with a lower priority (greater than 3) will not be
able to switch a camera to that same monitor.
Sequence that will be started when Video Loss is detected.
(Active only when Video Loss is enabled.) Sequence may
be selected using either sequence description or number.
Allows editing of the sequence which will be started when
Video Loss is detected (if Video Loss is enabled).
Enables automatic video restoration detection for this input.
Sets the priority level for video restoration sequence on this
input. (Active only when Video Restore is enabled.) Priority
can be set to a number between 0 and 255 with 0 being the
highest priority. The sequences are activated based on
priority. For example, if a sequence with priority 3 has a
camera switched to a monitor, and the sequence has locked
the monitor, a sequence with a lower priority (greater than 3)
will not be able to switch a camera to that same monitor.
Sequence that will be started when video is restored.
(Active only when Video Restore is enabled.) Sequence
may be selected using either sequence description or
number.
Allows editing of the sequence which will be started when
video is restored (if Video Restore is enabled).
Free-form field. (i.e., "High Resolution Color Camera
ACC484TP with ALM29V8F95 Manual Iris Lens. Plug-in
transformer located in Terminal Room B28.")
Enables selection of an alternate view for this input.
Used to specify the channel of the alternate view associated
with this input. (Active only when Alternate View is enabled.)