Figure 2-6 Dip Switches Of Hvbnet16Cpu - Honeywell VideoBloX User Manual

Hide thumbs Also See for VideoBloX:
Table of Contents

Advertisement

Figure 2-6 DIP Switches of HVBNET16CPU

DIP switch 1 is used to set communication parameters for the three serial ports.
Position
SW 1
Com 1 port baud rate
setting
SW 2
SW 3
Com 2 port baud rate
setting
SW 4
SW 5
Com 3 port baud rate
setting
SW 6
Switch Com1 between
SW 7
NETCPU & NETOSD
SW 8
Com 1 usage.
DIP switch 2 is used to restore, set communications parameters and set video source.
Position
Use
SW 1
Restore factory setting
SW 2
Com 1 type
SW 3
Com 2 type
SW 4
Com 3 type
SW 5
Use
SW2/SW4/SW6
0= NETOSD
1= NETCPU
0 = Show Linux debug info
1 = Set COM1 to be used for third-party
integration
To set to factory settings, set it to 1 during
reset. Then set it back to 0. (System IP will be
initialed together, the default IP is 192.168.1.9)
0= RS-232
1= RS-422
0= RS-232
1= RS-422
SW5 SW4
0
0
1
1
Description
SW1/SW3/SW5
0
0
0
1
1
0
1
1
Description
Type
0
RS232
1
RS422
0
RS485
1
Reserved
Honeywell
BAUD
RATE
9600
19200
38400
57600
11

Hide quick links:

Advertisement

Table of Contents
loading