PTZ CONTROL TIMEOUT
Enabled
Timeout
GENERAL <NO HEADING – FIELDS AT BOTTOM OF WINDOW>
Priority
Steps for Configuring Keyboard Detail
1. On the Keyboards screen, select the Detail tab on the right side of the window.
2. Select the Keyboard Number to be configured.
5. Enter/edit the Keyboard Name. Include the keyboard number in the name entered as
it does not appear on its own in displays or reports.
6. Enter/edit a Short Name for the keyboard.
7. Enter the physical Address of the keyboard.
8. Select the keyboard Type.
9. If this keyboard should automatically switch to a dedicated monitor, check the
Enabled box and enter the physical address of the dedicated monitor in the
Physical O/P field.
10. To run a sequence when a user logs in to this keyboard, Enable Login Sequence
and use either the Sequence Name or Sequence Number dropdown box to select the
Sequence to run. Edit the sequence as needed.
11. To run a sequence when a user logs out of this keyboard, Enable Logout Sequence
and use either the Sequence Name or Sequence Number dropdown box to select the
Sequence to run. Edit the sequence as needed.
12. To run a sequence when the keyboard establishes a connection, Enable the Connect
Sequence and use either the Sequence Name or Sequence Number dropdown box
to select the Sequence to run. Edit the sequence as needed.
13. To run a sequence when the keyboard connection is lost, Enable the Connect
Sequence and use either the Sequence Name or Sequence Number dropdown box
to select the Sequence to run. Edit the sequence as needed.
14. To automatically logout a user after a period of inactivity, Enable the Auto Logout.
Then select the Auto Logout time (in minutes).
15. To automatically timeout control of the PTZ after a period of inactivity, Enable the
PTZ Control Timeout, then select the Timeout period (in seconds).
16. Set the keyboard Priority with 0 indicating the highest priority.
17. Select
When enabled, sets a timeout for PTZ control after a period
of inactivity.
Used to set the period of inactivity (in seconds) after which
PTZ control will be lost.
Sets priority level for this keyboard. Priority can be set to a
number between 0 and 255 with 0 being the highest priority.
to save/download all information from the current page.