11. Environmental And Regulatory Specifications; 11.1 System Level Environmental Limits; 11.2 Serviceability And Availability; Table 54. System Environmental Limits Summary - Intel SR1500 - AXXMINIDIMM DDR-2 RAID Controller Cache Memory Manual

Server chassis/server system
Hide thumbs Also See for SR1500 - AXXMINIDIMM DDR-2 RAID Controller Cache Memory:
Table of Contents

Advertisement

10BEnvironmental and Regulatory Specifications

11. Environmental and Regulatory Specifications

11.1 System Level Environmental Limits

The table below defines the system level operating and non-operating environmental limits
Parameter
Operating Temperature
Non-Operating
Temperature
Non-Operating Humidity
Acoustic noise
Shock, operating
Shock, unpackaged
Shock, packaged
Vibration, unpackaged
Shock, operating
ESD
System Cooling
Requirement in BTU/Hr

11.2 Serviceability and Availability

The system is designed to be serviced by qualified technical personnel only.
The desired Mean Time To Repair (MTTR) of the system is 30 minutes including diagnosis of
the system problem. To meet this goal, the system enclosure and hardware have been
designed to minimize the MTTR.
Following are the maximum times that a trained field service technician should take to perform
the listed system maintenance procedures, after diagnosis of the system and having identified
the failed component.
Remove cover
Remove and replace hard disk drive
Remove and replace power supply module
Remove and replace system fan (non-hot swappable)
Remove and replace system fan (hot swappable)
Remove and replace backplane board
Remove and replace midplane board
Remove and replace control panel module
Remove and replace server board
80

Table 54. System Environmental Limits Summary

+10°C to +35°C with the maximum rate of change not to exceed 10°C per hour
-40°C to +70°C
90%, non-condensing @ 28°C
Sound Pressure: 55 dBA (Rack mount) in an idle state at typical office ambient
temperature. (23 +/- degrees C) Sound Power: 7.0 BA in an idle state at typical
office ambient temperature. (23 +/- 2 degrees C)
Half sine, 2 g peak, 11 mSec
Trapezoidal, 25 g, velocity change 136 inches/sec
Non-palletized free fall in height 24 inches (≧40 lbs to < 80 lbs)
5 Hz to 500 Hz, 2.20 g RMS random
Half sine, 2 g peak, 11 mSec
+/-15kV except I/O port +/-8KV per Intel Environmental test specification
3264 BTU/hour
Activity
Intel order number D31980-009
Intel® Server System SR2500AL
Limits
Time
Estimate
1 min
5 min
1 min
7 min
1 min
12 min
10 min
2 min
15 min
Revision – 1.6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr2500Sr2500al

Table of Contents