Basic format
Transmission from the computer begins with STX, then the command, parameter, and ETX are sent in this order. Add
parameters according to the details of control.
STX
A D
(2 byte)
Start (1 byte)
2 ID characters (2 bytes)
*
When sending commands without parameters, a colon (:) is not necessary.
Basic format (with sub command)
STX
A D
S1
S2
Sub command (5 bytes)
*
When transmitting a command which does not need a parameter, the operation (E) and parameter are not necessary.
Attention
If a command is transmitted after the lamp starts illuminating, there may be a delay in response or the command may not be
f
executed. Try sending or receiving any command after 60 seconds.
When transmitting multiple commands, be sure to wait until 0.5 seconds has elapsed after receiving the response from the
f
projector before sending the next command. When transmitting a command which does not need a parameter, a colon (:) is
not necessary.
Note
If a command cannot be executed, the "ER401" response is sent from the projector to the computer.
f
If an invalid parameter is sent, the "ER402" response is sent from the projector to the computer.
f
ID transmission in RS-232C supports ZZ (ALL) and 01 to 64, as well as 0A to 0Z groups.
f
If a command is sent with a specified ID, a response will be sent to the computer only in the following cases.
f
- It matches the projector ID.
Æ
- [PROJECTOR ID] (
page 66) is set to [ALL].
STX and ETX are character codes. STX shown in hexadecimal is 02, and ETX shown in hexadecimal is 03.
f
Chapter 6 Appendix - Technical Information
ID designate
ZZ, 01 to 06
I1
I2
;
C1
3 command characters (3 bytes)
Semi-colon(1 byte)
Same as basic format
I1
I2
;
C1
S3
S4
S5
E
Operation (1 byte)
"=" (Value specified using parameter is set)
C2
C3
:
P1
Colon(1 byte)
Parameter (underfined length) End (1 byte)
C2
C3
:
P1
P2
P3
P4
Parameter (6 bytes)*
Symbol "+" or " - " (1 byte) and set value or ad-
justment value (5 bytes)
P2
Pn
ETX
ETX
P5
P6