CHANGE/VIEW
FIELD DEFINITIONS:
System
Use the Up/Down arrows to select the desired Quik-Call II System. The number may also be entered directly.
The system may also be selected via the function keys. The radio may have a maximum number of 15 systems.
System Signalling Type
This field dictates the System Signalling Type to be used. It affects the values in the following fields:
Code A
Code B
Code C
Code E
The available signalling types include:
Motorola
GE
Plectron
Federal
The factory default is Motorola.
Signalling Muting Type
Use the Up/Down arrows to scroll through the available selections.
This field dictates the signalling Muting Type to be used during Quik-Call II operations: AND, OR.
AND - Both signalling Unmuting (Quik-Call) and Radio Unmuting must be satisfied to unmute.
OR -
Either Signalling Unmuting (Quik-Call) or Radio Unmuting must be satisfied to unmute.
The factory Default is AND.
Initial Squelch Type (this field is for view only).
This field dictates the Initial Squelch Type to be used upon entry to a Quik-Call II channel: Released, Quik Call.
The factory Default is Quik-Call.
Reset Type
Use the Up/Down arrows to scroll through the available selections.
This field dictates the Quik-Call II Call Reset Type to be used: Manual or Auto. When Manual Reset is selected
a Monitor button is required for proper Quik-Call II operations. The Factory Default is Auto.
Auto Reset Carr Ovrd
Use the Up/Down arrows to scroll through the available selections.
When this feature is enabled, the Auto Reset Duration will be reloaded into the Auto Reset Timer when the radio
mutes. The Factory Default is Enabled.
Auto Reset Duration (sec)
Use the Up/Down arrows to scroll through the available selections, or directly enter the desired value. Integer
values from 1 to 255 are allowed.
This field dictates the maximum amount of uninterrupted time spent in Release Squelch Mode. When this time
duration expires Release Squelch Mode will be exited and Quik-Call II Squelch Mode will be entered. The
Factory Default is 5 sec.
Decoder 1 Call Type
Use the Up/Down arrows to scroll through the available selections. This field dictates the Decoder 1 Call Type to
be used: Individual or Group. The Factory Default is Individual.