Infiniband Switch Module - HP Cluster Platform Express v2010 Overview

Workgroup system and cluster platform express overview and hardware installation guide
Hide thumbs Also See for Cluster Platform Express v2010:
Table of Contents

Advertisement

From
IB 24 Port Switch
Port 13
IB 24 Port Switch
Port 14
IB 24 Port Switch
Port 15
IB 24 Port Switch
Port 16
IB 24 Port Switch
Port 17
IB 24 Port Switch
Port 18
IB 24 Port Switch
Port 19
IB 24 Port Switch
Port 20
IB 24 Port Switch
Port 21
IB 24 Port Switch
Port 22
IB 24 Port Switch
Port 23
IB 24 Port Switch
Port 24
D.12 Two or Three c7000 Enclosures with Double-Density Server Blades
and Using the HP 4X DDR InfiniBand Switch Module
Configurations with either two or three c7000 enclosures and with double-density server blades
require two external InfiniBand switches to create a fully connected fabric. The wiring for two
enclosures can be derived from the three enclosure wiring tables by omitting the wiring for
Enclosure 3. The connection to Port 4 on the second external InfiniBand switch (IB-SW2) depends
on whether the configuration includes an external control node connected to the InfiniBand fabric
or not. If there is a control node connected to the InfiniBand fabric, the control node's HCA is
connected to that port. Otherwise, Port 4 on the second InfiniBand switch is connected to Port 8
on the InfiniBand switch installed in Interconnect Module Bay 5/6 on Enclosure 1.
Note:
The following wiring table describes the InfiniBand connections with respect to the first external
InfiniBand switch.
From
IB Switch 1 24 Port
Switch Port 1
IB Switch 1 24 Port
Switch Port 2
IB Switch 1 24 Port
Switch Port 3
92
Cabling Tables for CPE BladeSystem, with c7000 Enclosure Configurations
Label
To
Enclosure 1 Interconnect
IB-SW1-P13
Module 7/8 Port 5
Enclosure 1 Interconnect
IB-SW1-P14
Module 7/8 Port 6
Enclosure 1 Interconnect
IB-SW1-P15
Module 7/8 Port 7
Enclosure 1 Interconnect
IB-SW1-P16
Module 7/8 Port 8
IB-SW1-P17
N/A
IB-SW1-P18
N/A
IB-SW1-P19
N/A
IB-SW1-P20
N/A
IB-SW1-P21
N/A
IB-SW1-P22
N/A
IB-SW1-P23
N/A
Control node InfiniBand
IB-SW1-P24
HCA
Label
To
Enclosure 1 Interconnect
IB-SW1-P1
Module 5/6 Port 1
Enclosure 1 Interconnect
IB-SW1-P2
Module 5/6 Port 2
Enclosure 1 Interconnect
IB-SW1-P3
Module 5/6 Port 3
Label
Comment
E1-IMB7-P5
E1-IMB7-P6
E1-IMB7-P7
E1-IMB7-P8
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Only used if the control node is a
Control-P1
rack-mount server connected to the
InfiniBand fabric
Label
Comment
E1-IMB5-P1
E1-IMB5-P2
E1-IMB5-P3

Advertisement

Table of Contents
loading