HP Cluster Platform Express v2010 Overview page 109

Workgroup system and cluster platform express overview and hardware installation guide
Hide thumbs Also See for Cluster Platform Express v2010:
Table of Contents

Advertisement

Wiring Table for the Fourth InfiniBand Switch (IB-SW4)
From
IB Switch 4 24 Port
Switch Port 1
IB Switch 4 24 Port
Switch Port 2
IB Switch 4 24 Port
Switch Port 3
IB Switch 4 24 Port
Switch Port 4
IB Switch 4 24 Port
Switch Port 5
IB Switch 4 24 Port
Switch Port 6
IB Switch 4 24 Port
Switch Port 7
IB Switch 4 24 Port
Switch Port 8
IB Switch 4 24 Port
Switch Port 9
IB Switch 4 24 Port
Switch Port 10
IB Switch 4 24 Port
Switch Port 11
IB Switch 4 24 Port
Switch Port 12
IB Switch 4 24 Port
Switch Port 13
IB Switch 4 24 Port
Switch Port 14
IB Switch 4 24 Port
Switch Port 15
IB Switch 4 24 Port
Switch Port 16
IB Switch 4 24 Port
Switch Port 17
IB Switch 4 24 Port
Switch Port 18
IB Switch 4 24 Port
Switch Port 19
IB Switch 4 24 Port
Switch Port 20
IB Switch 4 24 Port
Switch Port 21
D.18 Wiring for a Configuration of Two or Three c7000 Enclosures with Double-Density Server Blades Using the HP BLc
Label
To
Enclosure 1 Interconnect
IB-SW4-P1
Module 5/6 Port 13
Enclosure 1 Interconnect
IB-SW4-P2
Module 5/6 Port 14
Enclosure 1 Interconnect
IB-SW4-P3
Module 5/6 Port 15
Enclosure 1 Interconnect
Module 5/6 Port 16
IB-SW4-P4
Not connected
Enclosure 1 Interconnect
IB-SW4-P5
Module 7/8 Port 13
Enclosure 1 Interconnect
IB-SW4-P6
Module 7/8 Port 14
Enclosure 1 Interconnect
IB-SW4-P7
Module 7/8 Port 15
Enclosure 1 Interconnect
IB-SW4-P8
Module 7/8 Port 16
Enclosure 2 Interconnect
IB-SW4-P9
Module 5/6 Port 13
Enclosure 2 Interconnect
IB-SW4-P10
Module 5/6 Port 14
Enclosure 2 Interconnect
IB-SW4-P11
Module 5/6 Port 15
Enclosure 2 Interconnect
IB-SW4-P12
Module 5/6 Port 16
Enclosure 2 Interconnect
IB-SW4-P13
Module 7/8 Port 13
Enclosure 2 Interconnect
IB-SW4-P14
Module 7/8 Port 14
Enclosure 2 Interconnect
IB-SW4-P15
Module 7/8 Port 15
Enclosure 2 Interconnect
IB-SW4-P16
Module 7/8 Port 16
Enclosure 3 Interconnect
IB-SW4-P17
Module 5/6 Port 13
Enclosure 3 Interconnect
IB-SW4-P18
Module 5/6 Port 14
Enclosure 3 Interconnect
IB-SW4-P19
Module 5/6 Port 15
Enclosure 3 Interconnect
IB-SW4-P20
Module 5/6 Port 16
Enclosure 3 Interconnect
IB-SW4-P21
Module 7/8 Port 13
4X DDR InfiniBand Gen2 Switch and External InfiniBand Switches
Label
Comment
E1-IMB5-P13
E1-IMB5-P14
E1-IMB5-P15
Connect if there is no rack-mount
E1-IMB5-P16
control node connected to the
InfiniBand fabric
Not connected because the
N/A
endpoint is used for
rack-mounted control node
E1-IMB7-P13
E1-IMB7-P14
E1-IMB7-P15
E1-IMB7-P16
E2-IMB5-P13
E2-IMB5-P14
E2-IMB5-P15
E2-IMB5-P16
E2-IMB7-P13
E2-IMB7-P14
E2-IMB7-P15
E2-IMB7-P16
E3-IMB5-P13
E3-IMB5-P14
E3-IMB5-P15
E3-IMB5-P16
E3-IMB7-P13
109

Advertisement

Table of Contents
loading

Table of Contents