From
IB Switch 1 24 Port
Switch Port 21
IB Switch 1 24 Port
Switch Port 22
IB Switch 1 24 Port
Switch Port 23
IB Switch 1 24 Port
Switch Port 24
Wiring Table for the Second InfiniBand Switch (IB-SW2)
From
IB Switch 2 24 Port
Switch Port 1
IB Switch 2 24 Port
Switch Port 2
IB Switch 2 24 Port
Switch Port 3
IB Switch 2 24 Port
Switch Port 4
IB Switch 2 24 Port
Switch Port 5
IB Switch 2 24 Port
Switch Port 6
IB Switch 2 24 Port
Switch Port 7
IB Switch 2 24 Port
Switch Port 8
IB Switch 2 24 Port
Switch Port 9
IB Switch 2 24 Port
Switch Port 10
IB Switch 2 24 Port
Switch Port 11
IB Switch 2 24 Port
Switch Port 12
IB Switch 2 24 Port
Switch Port 13
IB Switch 2 24 Port
Switch Port 14
IB Switch 2 24 Port
Switch Port 15
100
Cabling Tables for CPE BladeSystem, with c7000 Enclosure Configurations
Label
To
Enclosure 3 Interconnect
IB-SW1-P21
Module 5/6 Port 5
Enclosure 3 Interconnect
IB-SW1-P22
Module 5/6 Port 6
Enclosure 3 Interconnect
IB-SW1-P23
Module 5/6 Port 7
Enclosure 3 Interconnect
IB-SW1-P24
Module 5/6 Port 8
Label
To
Enclosure 1 Interconnect
IB-SW2-P1
Module 5/6 Port 9
Enclosure 1 Interconnect
IB-SW2-P2
Module 5/6 Port 10
Enclosure 1 Interconnect
IB-SW2-P3
Module 5/6 Port 11
N/A
Not connected
Enclosure 1 Interconnect
IB-SW2-P5
Module 5/6 Port 13
Enclosure 1 Interconnect
IB-SW2-P6
Module 5/6 Port 14
Enclosure 1 Interconnect
IB-SW2-P7
Module 5/6 Port 15
Enclosure 1 Interconnect
Module 5/6 Port 16
IB-SW2-P8
Not connected
Enclosure 2 Interconnect
IB-SW2-P9
Module 5/6 Port 9
Enclosure 2 Interconnect
IB-SW2-P10
Module 5/6 Port 10
Enclosure 2 Interconnect
IB-SW2-P11
Module 5/6 Port 11
Enclosure 2 Interconnect
IB-SW2-P12
Module 5/6 Port 12
Enclosure 2 Interconnect
IB-SW2-P13
Module 5/6 Port 13
Enclosure 2 Interconnect
IB-SW2-P14
Module 5/6 Port 14
Enclosure 2 Interconnect
IB-SW2-P15
Module 5/6 Port 15
Label
Comment
E3-IMB5-P5
E3-IMB5-P6
E3-IMB5-P7
E3-IMB5-P8
Label
Comment
E1-IMB5-P9
E1-IMB5-P10
E1-IMB5-P11
Not connected because the
N/A
endpoint is used for the control

node

E1-IMB5-P13
E1-IMB5-P14
E1-IMB5-P15
Connect if there is no
rack-mount control node
E1-IMB5-P16
connected to the InfiniBand
fabric
Not connected because the
N/A
endpoint is used for
rack-mounted control node
E2-IMB5-P9
E2-IMB5-P10
E2-IMB5-P11
E2-IMB5-P12
E2-IMB5-P13
E2-IMB5-P14
E2-IMB5-P15