Route Wires And Attach Connectors - Bosch VG5 800 SERIES Installation Manual

Autodome 800 series hd ptz camera
Table of Contents

Advertisement

AutoDome 800 Series HD PTZ Camera
3.4

Route Wires and Attach Connectors

Power wires must be routed to the left (front) side of the Power Supply Box through a
separate conduit. All video, control, and alarm wires must be routed through a second conduit
to the right side of the box. See Section 4 Cable and Wire Standards, page 51 for methods of
transmitting video and data, and for wire specifications.
WARNING!
External interconnecting cables are to be installed in accordance to NEC, ANSI/NFPA70 (for
US application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in
accordance to local country codes for all other countries.
Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch Rated
Fuses are required as part of the building installation. A readily accessible 2-pole disconnect
device with a contact separation of at least 3 mm must be incorporated.
There are two possible methods to route the video, control, and alarm wires:
Figure 3.3 VG4-A-PSU1 or VG4-A-PSU2 Power Supply Box
1
2
3
4
Bosch Security Systems, Inc.
One is to route the power, ethernet, and alarm wires through the conduit fitting on the
right (front) side of the Power Supply Box and out to the AutoDome Interface Board.
P101
24V
NC 24V
P106
GND TXD RXD
C+ C-
120 VAC/230 VAC Power In
P101 Connector
Ground Connection
Transformer
The second method is to bypass the Power Supply Box and route the ethernet and alarm
wires directly to the Interface Board. You connect only the power wires inside the Power
Supply Box.
Installation Manual
Installing Roof Parapet and Pipe Mounts | en
J102
(LED)
P105
GND TXD RXD
C+ C-
5
Ethernet Video and Control Wire
6
24 VAC Power Out
7
P107 Connector
37
F.01U.273.797 | 5.0 | 2012.08