Attach Housing to the Interface Box Secure Housing to Ceiling Preparing the Bubble Replacing an In-ceiling Rugged Polycarbonate Bubble Replacing an In-ceiling Acrylic Bubble Replacing an In-ceiling HD Acrylic Bubble Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 4
Recording media 20.1.3 Activating and configuring storage media 20.1.4 Formatting storage media 20.1.5 Deactivating storage media 20.2 Recording Profiles 20.3 Maximum Retention Time 20.4 Recording Scheduler 20.5 Recording Status Alarm 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 5
25.1.15 Storage, CPU and network status 25.2 Playback 25.2.1 Selecting the recording stream 25.2.2 Searching for recorded video 25.2.3 Exporting recorded video 25.2.4 Controlling playback Operation 26.1 Using Intelligent Tracking Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 6
| Table of contents AUTODOME IP starlight 7000 HD 26.2 Recommended Use of Your Camera Troubleshooting Maintenance Technical data User Command Table 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Legal Information Copyright This manual is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly.
16. Attachments, changes or modifications - Only use attachments/accessories specified by the manufacturer. Any change or modification of the equipment, not expressly approved by Bosch, could void the warranty or, in the case of an authorization agreement, authority to operate the equipment.
Page 10
Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information.
Page 11
60950-1. UL Certification does not cover the performance or reliability of the security or signaling aspects of this product. UL MAKES NO REPRESENTATIONS, WARRANTIES, OR CERTIFICATIONS WHATSOEVER REGARDING THE PERFORMANCE OR RELIABILITY OF ANY SECURITY OR SIGNALING-RELATED FUNCTIONS OF THIS PRODUCT. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
High Power-over-Ethernet (High PoE): This unit can by powered via High PoE. To power the unit this way, use only approved High PoE devices – those offered or recommended by Bosch. High PoE can be connected at the same time as a 24 VAC power supply. If auxiliary power (24 VAC to camera and to heater) and High PoE are applied simultaneously, the camera...
Verify that all the parts listed in the Parts List below are included. If any items are missing, notify your Bosch Security Systems Sales or Customer Service Representative. – Do not use this product if any component appears to be damaged. Please contact Bosch Security Systems in the event of damaged goods. –...
| Unpacking AUTODOME IP starlight 7000 HD Mounting Options Part Numbers Bosch High PoE 60W midspan NPD-6001A Corner Mount Kit – Corner Mount Plate VG4-A-9542 Mast (Pole) Mount Kit – Mast Mount Plate VG4-A-9541 – Fiber Optic Ethernet Media Converter Kit...
Page 15
Pipe Mount Barrel connector – Roof parapet Mount – Pipe Mount Only if installing a fiber optic model Appropriate tool for In-ceiling Mount cutting a hole in drywall or ceiling tile Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 16
| Unpacking AUTODOME IP starlight 7000 HD Pliers In-ceiling Mount 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
AUTODOME IP starlight 7000 HD Unpacking | en Additional Products Required The following table lists additional products, sold separately by Bosch or other manufacturers, necessary to install AUTODOME cameras. Quantity Product Part Number Size SD card (user-supplied) Water tight metal conduit (user-supplied) 20 mm (0.75 in.)
(not supplied). Warning! To minimize the potential for corrosion on the housing, use only Bosch hardware and mounts. See number 5 (Installation in a corrosive environment) in the section Recommended Use of Your Camera, page 143 for more information.
Cameras attached to a pole, roof, or to a bridge are especially vulnerable. Bosch offers the following recommendations to stabilize an AUTODOME 7000 and to decrease the affects of vibration on transmitted images, privacy masks, and Intelligent Tracking.
(such as wearing grounded wrist straps) to avoid electrostatic discharge. Warning! Bosch recommends disconnecting power to the camera while adding or removing an SD card. Follow the steps in one of these sections (depending on the type of camera mount): Remove the bubble from an in-ceiling housing, page 65 or Remove the bubble from a pendant housing, page 65.
100–380 mm (4–15 in.). You must use a banding tool (sold separately) for a mast or pole installation. Follow the instructions provided with the banding tool to securely mount the Mast Plate to the pole. Contact your Bosch Sales Representative to order Banding Tool P/N TC9311PM3T.
Page 23
Warning! For units intended to be installed outdoors: All wiring (power and I/O cabling) connecting to the unit must be routed separately inside different permanently earthed metal conduits (not supplied). Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
To connect alarm inputs and outputs, attach the supplied 6-pin Alarms In and the 4-pin Alarms Out connector plugs with flying lead wires to the appropriate incoming alarm wires. Alarm Out 4 is a relay. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 25
If you are connecting supervised alarms and relays, attach the supplied 7-pin Relay Connector to the appropriate incoming wires. Refer to Make Connections in the Power Supply Box, page 32 for additional information. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 26
Series cameras: If you are mounting an AUTODOME 7000 Series camera to an ARM mount that was wired for an earlier model of Bosch AUTODOME, you must either re-wire cable 8 to be audio input and output, or disconnected it from the power supply.
Page 27
Warning! For units intended to be installed outdoors: All wiring (power and I/O cabling) connecting to the unit must be routed separately inside different permanently earthed metal conduits (not supplied). Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
To properly wire the incoming high voltage and the outgoing low voltage lines, refer to this table: Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Ground Grounding Screw 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 29
Ensure that you connect the outgoing power supply wires to the P107 heater connectors (HN and HL). The heater power (XF103) fuse can handle a higher amperage (3.15 A) than the camera power (XF102) fuse (2.0 A). Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
The bottom hinge pin of the Pendant Arm is provided with a Hinge Pin Stop to hold the hinge open while attaching the arm to the Power Supply Box. Compress the bottom hinge pin by pushing the pin lever downward and rotating it behind the Hinge Pin Stop. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 31
Serious injury or death can occur if the hinge pins of the Pendant Arm are not fully engaged (locked) to the Power Supply Box. Exercise caution before releasing the Pendant Arm. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
After all wiring is complete, close the cover door and tighten the two (2) captive screws on the cover door to 10-12 N-m (90-105 in.-lbs) to ensure the Power Supply Box is watertight. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Follow the instructions provided with the banding tool to securely mount the Mast Plate to the pole. Contact your Bosch Sales Representative to order Banding Tool P/N TC9311PM3T.
Page 34
Route and Connect Wires to a Power Supply Box The illustration below depicts the power and control cables connected to the Pendant Arm: Figure 7.12: Pendant Arm Cables Cable Cable Grounding Strap (black) UTP Video/Ethernet (blue) 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 35
Wire input conduit holes Connect the incoming 24 VAC power wires to the 5-pin, 24 VAC Power In mating connector (supplied with the Mounting Plate kit) for the camera and for the Heater. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Tilt the bottom of the dome toward the pendant arm base and place the mounting hook, located on top of the dome housing, over the recessed hinge pin of the arm. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 37
10-12 N-m (90-105 in.-lbs). Caution! You must tighten the two mounting screws to a minimum torque of 10-12 N-m (90‑105 in.-lbs) to ensure a proper seal between the arm and the housing. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
The VGA-ROOF-MOUNT is a stationary mount intended for rooftop parapet vertical walls. It is made of light weight aluminum with a corrosion-resistant finish and is used for all Bosch AUTODOME cameras up to a rated load of 29 kg (64 lb). This mount can be fitted to the inside or outside of parapet walls and can swivel for ease of positioning and for servicing the camera.
Page 39
Method Two is to bypass the Power Supply Box and route the video, control, and alarm wires directly to the Interface Board. You connect only the power wires inside the Power Supply Box. All conduit and junction boxes used must be electrically earth-grounded. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 40
Notice! The Power Supply Box with transformer comes with a barrier that separates the high voltage side on the left from the low voltage 24 VAC side on the right. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 41
Route the control wires from the Power Supply to the Pipe Interface Board. Then attach the supplied six (6) pin control data connector to the wires in the Power Supply Box. Refer to Wire the Pipe Interface Board, page 49. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 43
T 2.0 A T 3.15 A The following table lists the Power Supply Box connectors: Connector Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Ground Grounding Screw Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
When the hinges are aligned, release the top hinge pin to engage its mating hinge on the power box. Then release the bottom hinge pin from the Hinge Pin Stop to complete attaching the Cover Door to the Power Supply Box. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Apply sealant around each fastener hole Parapet Wall Bracket Roof Mount Plate 3/8-16 SS Hex Head Bolt Use a minimum of six (6) fasteners (not (supplied) supplied). Eight (8) fastener holes shown. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 46
Make sure all surfaces are clean and dry. Apply a bead of sealant completely around the leading threads of the male fitting. Force the adhesive into the threads to thoroughly fill all voids. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Customer must supply 1-1/2 inch (NPS) pipe threaded on both ends with a minimum length of 5 inches (12.7 cm). You must use Teflon tape for thread-sealing compound. All screws shall be tightened securely. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 48
Thread the Pipe Cap onto the down pipe and tighten securely to prevent leaks. Warning! You must thread the Dome Cap onto the pipe until it is tight. Failure to do so can result in damage or serious injury or death. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
This section provides instructions for connecting wires and cables to the Pipe Interface Board, as illustrated below. Refer to the Connection, page 73 chapter for cable and wiring recommendations and specifications. AGND OUT 3 OUT 2 OUT 1 Figure 8.25: Pipe Interface Board Connections Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 50
OUT – (Audio out signal ground) Signal Ground Alarms In (EOLR P104 Ground Supervised, 1-2) 26-16 Alarm 2 Alarm 1 Earth Ground Relay Output P104 Normally Closed 26-16 Common Normally Open 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 51
Alarms Out connector plugs with flying lead wires to the appropriate incoming alarm wires. Alarm Out 4 is a relay. WHITE BROWN P102 ORANGE GREEN WHITE BROWN ORANGE P103 GREEN YELLOW BLUE P104 Figure 8.26: Alarm and relay connectors Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 52
Dome Cap. Caution! Be careful not to strip the threads when tightening the Pipe Interface Board retaining screws. Figure 8.27: Pipe Interface Board to Dome Cap Assembly Interface Board 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Hold the housing firmly in position and alternately tighten the two (2) 5-mm Allen head mounting screws from above to a torque value of 10-12 N-m (90-105 in.-lbs). Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Connect the 24 VAC to Dome plug, installed previously, to its mating connector P107 on the right side of the box. Connect the 115/230 VAC, 3-pin Power-in plug, installed previously, to its mating connector P101 on the left side of the box. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Place the Bracket Assembly over the ceiling tile, which is used to mount the camera. Snap the Bar Clips of the bracket to the ceiling rails. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 56
Figure 9.31: Cut Hole in Ceiling Tile Tighten the four (4) securing screws to the Bracket Assembly. Figure 9.32: Tighten Bracket Securing Screw Secure the Bracket Assembly to an overhead securing point with a safety wire. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Attach a 3/4-inch NPS (20-mm) conduit fitting to the hole in which you bring in the wires. Be sure to thread the inside nut to the conduit fitting. Route the video, control, power, and alarm wires through the conduit fitting and into the Interface Box. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 58
To connect supervised alarms and relays, attach the appropriate wires to their terminals on the P104 connector on the Pipe Interface Board. Refer to the Connection, page 73 chapter for more details on wiring alarms. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Carefully slide the gasket down over the housing, until it rests on the flange of the housing. Attach Housing to the Interface Box The In-Ceiling Housing is attached to the Interface Box and secured by two (2) thumbscrews. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 62
The In-ceiling dome is provided with tether points on each side of the housing. To prevent injury, attach a safety wire from a secure anchor point above the ceiling to a tether point on the dome housing. See below for an illustration. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
40 mm 1.57 in. MAXIMUM CEILING 6.5 mm 0.26 in. MINIMUM CEILING inches Figure 9.40: Secure camera to ceiling Tether Point Ceiling Clamp Ceiling Clamp Rotate Clockwise to Engage Clamp Tether Point Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 64
Over-torquing the Ceiling Clamps can damage the clamp or ceiling. Only tighten the clamp until it contacts the ceiling and you start to feel some resistance. If using a power screwdriver, set the torque level to the lowest setting. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Notice! To avoid excessive moisture saturation inside the housing, limit the amount of time that the bubble is disconnected from the housing. Bosch recommends that the bubble be removed from the housing for no more than five (5) minutes. Remove the bubble from an in-ceiling housing Loosen the lockscrew (item 1 in the illustration below) in the trim ring using a P1 or smaller Phillips screwdriver until the bubble can rotate freely.
Page 66
Place the black trim ring over the inner ring. Replace and tighten the four (4) screws. Replace the bubble in an in-ceiling housing Figure 10.43: In-Ceiling Bubble 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 67
Replace the bubble in a pendant housing Insert the bubble and trim ring assembly into the pendant housing. Rotate the assembly clockwise until it locks. The latch mechanism makes a click when it locks. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
3. Turn over the bubble and trim ring assembly so that you see the inside of the assembly. 4. Remove the four Phillips screws (item 2 below), using a P1 Phillips screwdriver, that connect the bubble to the trim ring and set aside for later use. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 69
9. Clean the bubble according to the instructions in the section “Maintenance.” 10. Place the replacement bubble and trim ring assembly onto the in-ceiling housing, and rotate it clockwise approximately 1/4 turn until it stops. Then tighten the lock-screw. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
5. Clean the bubble according to the instructions in the section “Maintenance.” 6. Place the replacement bubble onto the in-ceiling housing, and rotate it clockwise approximately 1/4 turn until it stops. Then tighten the lock-screw. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Forcing the screw into the trim ring (without the screw going into the screw slot in the housing) can deform the ring. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
8. Clean the bubble according to the instructions in the section “Maintenance.” 9. Insert the replacement bubble and trim ring assembly into the pendant housing, and rotate it clockwise until it locks. The latch mechanism makes a click when locks. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
IP Connection Network Switch Computer Notice! You can also use the Bosch Video Client software application to configure the network settings for an AUTODOME 7000 Series camera. Go to www.boschsecurity.com to download the Configuration Manager software and Operating Manual. 15.2...
IP network using the built-in Web server. In addition, power can be supplied over the Ethernet cable using the Bosch High PoE 60W midspan (sold separately). Power can also be supplied over the Ethernet cable to in-ceiling models and indoor/outdoor pendant models used in indoor applications (where the heater is not powered) using PoE+ PSEs (midspan switches) compliant with the IEEE 802.3at, class 4 standard.
100 m (328 ft) Bandwidth 10 Base-T/100 Base-TX High PoE (required for pendants in outdoor applications that use Use the Bosch High PoE 60W midspan heaters) (sold separately). PoE+ (only for indoor models or indoor applications for pendant model IEEE 802.3at, class 4 standard...
Ground (Pin 7) From Configuration, select Interfaces > Alarm Inputs, select the number of the Alarm input and finally, select N.O. See the table below for contact and condition details. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 77
Configuring a Normally Open Non-supervised Alarm Connect the alarm to the appropriate input (3 through 7) and ground at the camera. Figure 15.48: N.O. - Normally Open Non-supervised Connections Dry Contact Dome Connector Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 78
5 and 32 V to complete the circuit, with a maximum voltage rating of 32 VDC @ 150 ma. Connect the appropriate stripped wire to the open connector (1, 2, or 3) of the transistor. Connect the appropriate stripped wire to the ground (GND) connector. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Remove the 100 Ohm termination resistor from the C+ to C- terminals. Connect the audio line level source to the Audio_In+ (C+) input terminal. Connect the audio signal ground to the Audio_In- (C-) input terminal. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 80
Audio_Out– (TXD) Signal Ground Notice! Separate the audio cables from the AC power lines to avoid noise. To configure audio on the camera, refer to Basic Mode: Audio or Audio. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
You can find notes on using Microsoft Internet Explorer in the online Help in Internet Explorer. If you choose to use a computer running Microsoft Internet Explorer or any of the Bosch software, the computer must conform to the following minimum requirements: –...
If you do not connect, the unit may have reached its maximum number of connections. Depending on the unit and network configuration, each camera can have up to 50 Web browser connections or up to 100 connections via the Bosch Video Management System (BVMS).
Page 83
All settings are backed up in camera memory so they are not lost even if the power fails. The exception is the time settings, which are lost after 1 hour without power if no central time server is selected. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Make sure that the display does not go beyond the green zone during modulation. For more information, refer to Audio. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
(switching to summer time and back to normal time). First check whether the correct time zone is selected. If it is not correct, select the appropriate time zone for the system, and click the Set button. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Custom option. Or it can be set to Off for no overlay information. Select the desired option from the list. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 88
Enter the interval (in seconds) between insertions of the digital signature. Signature intervals Select the interval (in seconds) for the signature. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Enter the ID of the device. Device port Enter the number of the device port. The default is 5060. Password Enter the appropriate password. Alarm device ID Enter the ID of the alarm device. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
You can specify the interval at which the individual images should be generated for the M- JPEG image on the LIVE page. JPEG quality You can specify the quality at which the JPEG images appear on the LIVE page. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
LIVE page. If necessary, click Browse to find a suitable directory. Video file format Select a file format for the live page display. The MP4 format does not include metadata. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
All parameters combine to make up a profile and are dependent on one another. If you enter a setting that is outside the permitted range for a particular parameter, the nearest permitted value will be substituted when the settings are saved. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 93
Skipping frames can be particularly advantageous for networks with low bandwidths. The image rate in frames per second (fps) appears next to the text field or slider. Video resolution Select the desired resolution for the video image. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 94
Maximum bit rate. Background delta QP Select the appropriate encoding quality level for a background region defined in Encoder Regions. The lower the QP value, the higher the encoding quality. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
- H.264 MP 400x720 upright (cropped)* - H.264 MP D1 4:3 (cropped)* - H.264 MP 640x480 *This option is available for 1080p models only. Non-recording profile Select one of the following profiles for each stream: Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Eight encoder regions can be defined. To define encoder regions, follow these steps. From the first drop-down box (the unlabeled Regions selection list), select one of the eight available regions. (The drop-down box has the default option of Region 1). 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
10. The mask expands by 10% for a few seconds to illustrate how much the mask size will increase during Pan/Tilt movement. 11. To hide an individual mask, select the mask number and clear the Enabled check box. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Sodium Lamp: Optimizes the sodium vapor light to restore objects to their original color. Red Gain The red gain adjustment offsets the factory white point alignment (reducing red introduces more cyan). 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 99
This is accomplished by integrating the signal from a number of consecutive video frames to reduce signal noise. If you select this option, the camera disables Shutter automatically. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 100
Turns on the 2D and 3D noise reduction feature. Noise Reduction Level Adjusts the noise level to the appropriate level for shooting conditions. Select a value between 1 and 5. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Select Standard (default) to enable this feature in standard mode. Select Enhanced to enable this feature in enhanced mode. Select Off to disable this feature. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Sets the left Auto Pan limit of the camera. Use the preview window to move the camera to the left pan limit and click the button. The camera will not move past this limit when in Auto Pan Between Limits mode (AUX 2 ON). 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 103
SW, W, NW) heading in which the camera is pointing. Notice! The compass feature is not compatible with Bosch’s Intelligent Tracking feature. If Intelligent Tracking is activated, the camera automatically disables the display of the compass heading. Once Intelligent Tracking is deactivated, the camera returns the compass heading to the display.
Select the appropriate function from the drop-down list. Function Description Start auto pan Start auto pan with limit Stop auto pan Start custom tour Stop custom tour Start tour Stop tour Start playback A 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 105
OSD feedback on OSD feedback off IR mode on IR mode off IR mode auto Visible light on Visible light off Visible light inhibit on Visible light inhibit off Auto tracker on Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Select a format for audio recording. The default value is AAC 48 kbps. You can select AAC 80 kbps, G.711 or L16 depending on the required audio quality or sampling rate. AAC audio technology is licensed by Fraunhofer IIS. (http://www.iis.fraunhofer.de/amm/) 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
To change the shape of a zone, place the cursor over the edge of the zone, hold down the mouse button and drag the edge of the zone to the required position. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
It is also possible to let the VRM Video Recording Manager control all recording with accessing an iSCSI system. This is an external program for configuring recording tasks for video servers. For further information please contact your local customer service at Bosch Security Systems Inc.
Select the encoder profile setting that is to be used with stream 1 and 2 when recording. This selection is independent of the selection for live stream transmission. (The properties of the encoder profiles are defined on the Encoder Profile page.) Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 110
Here you can select the alarm sensor that is to trigger a recording. Virtual alarm Here you can select the virtual alarm sensors that are to trigger a recording, via RCP+ commands or alarm scripts, for example. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Recording | en 111 Notice! For more information, please see the Alarm Task Script Language document and the RCP+ documentation. For the latest version of these documents access your Bosch product catalog on the Internet. Export to account Select this parameter if you want all alarm recordings to be exported to an FTP server automatically.
The graphic indicates the recording activity of the camera. You will see an animated graphic while recording is taking place. 20.5 Recording Status Details of the recording status are displayed here for information. These settings cannot be changed. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
VIDOS or Bosch Video Management System, you can store a general password here. The camera can use this general password to connect to all remote stations protected with the same password.
Page 114
Auto-connect Select the On option to automatically re-establish a connection to one of the previously specified IP addresses after each reboot, after a connection breakdown or after a network failure. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 115
If you select the option Silent VCA, then the system creates metadata to facilitate searches of recordings but no alarm is triggered. You cannot change any parameters for this configuration. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 116
Notice! Additional analysis algorithms with comprehensive functions such as IVMD and IVA are available from Bosch Security Systems Inc. If you select one of these algorithms, you can set the corresponding parameters here directly. You can find information on this in the relevant documents on the product CD supplied.
Page 117
This allows you to avoid false alarms triggered by short-term changes, for example cleaning activities in the direct field of vision of the camera. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 118
Appearing edges Select this option if the selected area of the reference image includes a largely homogenous surface. If structures appear in this area, then an alarm is triggered. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Notice! First set up normal audio transmission before you configure the audio alarm here (see Audio). Audio alarm Select On if you want the device to generate audio alarms. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Name The name makes it easier to identify the alarm in extensive video monitoring systems, for example with the VIDOS and Bosch Video Management System programs. Enter a unique and clear name here. Do not use any special characters, for example &, in the name. Special characters are not supported by the system's internal management.
(for example, 1: Input 1). – IVA/MOTION+: If you select this option, then an alarm will begin when IVA or motion detection is activated. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 122
5. Click Set to save. The camera’s system activates the alarm rules. (Refer to the User Command Table, page 149 in the User / Operation Manual for a list of all AUX commands for your camera.) 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Bistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select 10 s. Output name Enter a name for the alarm output. Toggle Click the button to test the relay / output connection. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
If a DHCP server is employed in the network for the dynamic assignment of IP addresses, you can activate acceptance of IP addresses automatically assigned to the camera. Certain applications (Bosch Video Management System, Archive Player, Configuration Manager) use the IP address for the unique assignment of the unit. If you use these...
Page 125
You can set the maximum segment size for the IP packet's user data. This gives you the option to adjust the size of the data packets to the network environment and to optimize data transmission. Please comply with the MTU value of 1,514 bytes in UDP mode. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Select Auto to allow the camera to poll the server a few times; if no contact is made, it stops polling. – Select On to constantly poll the server. – Select Off to block polling. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
For example, access to the unit can then be made using Windows Explorer without knowledge of the IP address of the unit. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
The settings must be made individually for each stream. Enable To enable simultaneous data reception on several receivers you need to activate the multicast function. To do this, check the box. You can then enter the multicast address. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Date/time suffix The date and time are automatically added to the file name. When setting this parameter, ensure that the unit's date and time are always correctly set. Example: the file snap011005_114530.jpg was stored on October 1, 2005 at 11:45 and 30 seconds. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Use this setting to configure a filter that allows or blocks network traffic that matches a specified address or protocol. IP Address 1 / 2 Enter the IPv4 address that you want to allow or block 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 131
AUTODOME IP starlight 7000 HD Network | en 131 Mask 1 / 2 Enter the subnet mask for the appropriate IPv4 address. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
The installation code of the unit is also displayed here. 24.3 Certificates Usage list HTTPS server Select the default certificate for the HTTPS server. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Click the REFRESH button to reload log data. 24.5 System Overview This window is for information only and cannot be modified. Keep this information at hand when seeking technical support. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 134
134 en | Service AUTODOME IP starlight 7000 HD Select the text on this page with a mouse and copy it so that it can be pasted into an e-mail if required. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Note: If the preposition is already stored, a dialog box displays the message, “Overwrite current preposition?” Click OK to overwrite, or click Cancel to cancel the operation. Click to display the selected preposition in the video image. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Click this button to display the home position of the camera. Focus Click this button to activate the Auto Focus mode on the camera. The OSD displays the message, “OSD: Camera [number] / Auto Focus: ONE PUSH.” 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Click this button to activate the Auto Focus mode on the camera. The OSD displays the message, “OSD: Camera [number] / Auto Focus: ONE PUSH.” Custom tour Click this button to view a custom tour that was previously configured. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
This information can help with problem solving or when fine tuning the unit. For example: – if the storage activity is too high, change the recording profile, – if the CPU load is too big, change the VCA settings, 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Select the playback speed using the speed regulator – Jump to start of active sequence or to previous sequence – Jump to start of the next video sequence in the list Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Factors such as the viewing angle and unwanted motion (from trees, for example) may interfere with Intelligent Tracking operation. Use the following recommendations to ensure smooth Intelligent Tracking operation: – Mount/Mounting Surface Stability 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Page 141
Click: In this mode, users can click an object moving in the live video image to enable the camera to track the movement of the selected object. This mode is most useful for scenarios where normal scene activity is expected. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 142
The camera will restart tracking if a target starts moving in the same area where the initial target stopped moving or if the camera detects an object moving along the last known trajectory. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
If you must remove the bubble (for example, to install or remove an SD card), do not leave the bubble off of the dome for longer than five minutes. Bosch also recommends that you keep the dome camera in its packaging until you are ready to install the camera.
Page 144
SD cards for recording. Bosch is not liable for any damage that results from missing video information. Bosch does not make any commitments or promises regarding quality, performance, or other features with respect to third party products (such as SD cards).
Check that the camera lens cover is removed. If O.K., then: – Check that the maximum Ethernet cable distance has not been exceeded. If O.K., then: – Restore all camera settings via the Settings menu. Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 146
- In the Base frame rate field, choose either 25 ips or 30 ips. – Check the integrity of all connectors and splices of the Ethernet cable. If O.K., then: – Contact Bosch Technical Support. Loss of Privacy when – Web browsers, BVC or BVMS using Privacy Mask –...
Page 147
Never scrub the bubble with any abrasive material or cleaners. Bosch recommends cleaning the exterior of the bubble with NOVUS “No. 1” Plastic Clean & Shine (or equivalent), according to manufacturer’s instructions. Refer to www.novuspolish.com to order or to find a local distributor.
For product specifications, see the datasheets for AUTODOME IP 7000 Series and for AUTODOME HD 7000 Series, available on the appropriate product pages of the Online Product Catalog at www.boschsecurity.com. 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
(HD models only) On/Off Intelligent Tracking Turns Intelligent Tracking on or off On/Off Digital Zoom Lock Turns digital zoom on and off On/Off Sector Blanking On–enable Off–disable On/Off Privacy Masking On–enable Off–disable Bosch Security Systems Operation Manual 2016-07 | 1.0 | F.01U.283.679...
Page 150
Turbo mode On – activates turbo mode Off – deactivates turbo mode Set/Shot 901-999 Adds or removes Set ###–adds preset to tour presets from tour Shot ###–removes preset from tour 2016-07 | 1.0 | F.01U.283.679 Operation Manual Bosch Security Systems...
Need help?
Do you have a question about the VG5-7230-CPT5 and is the answer not in the manual?
Questions and answers