Route Wires And Attach Connectors - Bosch VG4 Series Installation Manual

Modular camera series
Hide thumbs Also See for VG4 Series:
Table of Contents

Advertisement

VG4 Modular Camera Series
4.
5.
6.
2.4

Route Wires and Attach Connectors

Power wires must be routed to the left (front) side of the Power Supply Box through a
separate conduit. All video, control, and alarm wires must be routed through a second conduit
to the right side of the box.
If you plan to route the power through an intermediate power supply box, refer to
Section 2.5 Route Power through Intermediate Power Supply Box, page 21.
WARNING!
External interconnecting cables are to be installed in accordance to NEC, ANSI/NFPA70 (for
US application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in
accordance to local country codes for all other countries.
Branch circuit protection incorporating a 20 A, 2-pole Listed Circuit Breaker or Branch Rated
Fuses are required as part of the building installation. A readily accessible 2-pole disconnect
device with a contact separation of at least 3 mm must be incorporated.
Figure 2.2 Pendant Arm Power Supply Box
Bosch Security Systems, Inc.
Installing the Pendant Arm Wall, Corner, and Mast (Pole) Mounts | en
Secure the Power Supply Box to the mounting surface.
For a Wall installation: Use four (4) corrosion-resistant, stainless steel studs (not
supplied). Then proceed to Step 5 below.
For a Corner installation: Secure the Corner Plate to the wall corner using four (4)
studs (not included). Then proceed to Step 5 below.
For a Mast or a pole installation: The metal straps included with the Mast mount
accommodate a pole with a diameter of 100–380 mm (4–15 in.). You must use a
banding tool (sold separately) for a mast or pole installation. Follow the instructions
provided with the banding tool to securely mount the Mast Plate to the pole.
Contact your Bosch Sales Representative to order Banding Tool P/N TC9311PM3T.
Secure the Power Supply Box to the Corner Plate or Mast Plate using the four (4) 3/8 x 1-
3/4-inch bolts and split lock washers (supplied).
Attach 3/4-inch (20-mm) NPS watertight pipe fittings (not supplied) to the bottom or
back holes of the Power Supply Box through which you will run the power, video, and
control data wires.
24 VAC
P101
24V
NC
24V
P106
P105
GND T XD R XD
C+ C-
GND T XD R XD
Installation Manual
J102
(LED)
C+ C-
17
F.01U.162.025 | 6.0 | 2010.03

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents