STEP 9 – (115V MOTOR): WRAP CAPACITOR INSULATING SLEEVE (D55248) AROUND 25MFD CAPACITOR
(SL6-59) AND FIT INSULATING DISC (D55250) ONTO CAPACITOR STUD. FIT CAPACITOR STUD THROUGH
MOUNTING HOLE IN GEARBOX HOUSING AND SECURE WITH M8 NUT AND SHAKEPROOF WASHER,
ALIGNING NOTCH IN CAPACITOR INSULATING SLEEVE WITH BRACKET ON GEARBOX HOUSING.
CONNECT THE GREY WIRES FROM MOTOR AND WIRING LOOM (D55246) TO ONE TERMINAL OF THE
CAPACITOR AND CONNECT THE BLACK WIRES FROM MOTOR AND WIRING LOOM TO THE OTHER
TERMINAL OF THE CAPACITOR. CONNECT THE WHITE MOTOR WIRE TO THE WHITE LOOM WIRE WITH
THE IN LINE CONNECTORS. TIE THE ENDS OF THE CAPACITOR INSULATING SLEEVE TOGETHER USING 3
X CABLE TIES (SL17-144). POSITION THE WIRES THROUGH THE SLOTS IN THE END OF THE INSULATING
SLEEVE AND TIE THE WIRE LOOM TO THE GEARBOX END PLATE USING 1 X CABLE TIE.
NOTE – REMAINDER OF ASSEMBLY PICTORIALLY FOLLOWS STEPS 12 TO 13 ABOVE WITH THE
EXCEPTION OF THE INCOMING MAINS WIRES BEING HARD WIRED TO THE MAIN PCB (SL17-312) USING
FAST-ONS AND THE FINISHED GEARBOX ASSEMBLY FOR THE 115V VERSION BEING A55251.