SECTION 3 – TOP CASING
ALL MODELS
Removal :-
1. Lower operating handle and lock in position where applicable.
2. Lift binder onto its back and rest on desk.
3. Unscrew three torx head screws from underside front edge of bottom casing.
4. Lower binder onto its base.
5. Unscrew two torx head screws from back edge of top casing.
6. Unlock and lift operating handle to fully raised position.
7. Lift off top casing (together with wire closing lid where appropriate).
Replacement :-
1. Lift operating handle to fully raised position.
2. Place top casing on top of lower casing and engage lip feature around mating edge of casings.
3. Replace two torx head screws into holes at back edge of top casing.
4. Lower operating handle and lock in position where applicable.
5. Lift binder onto its back and rest on desk.
6. Replace three torx head screws into holes in underside front edge of bottom casing.
7. Lower binder onto its base.