STEP 10 – (230V MOTOR): CONNECT THE WIRES FROM THE MOTOR TO THE 9MFD CAPACITOR AS
FOLLOWS; GREY WIRE TO TOP LEFT FLAG ON CAP, BLACK WIRE TO TOP RIGHT FLAG ON CAP.
THREAD THE END OF THE WIRING LOOM THROUGH THE LOOSE CABLE TIE. CONNECT THE
WHITE WIRE FROM THE MOTOR TO THE WHITE WIRE ON THE WIRING LOOM D55226 CONNECT
THE BLUE WIRE FROM THE LOOM TO THE FLAG ON THE CAP UNDERNEATH THE GREY WIRE,
CONNECT THE BLACK WIRE ON THE LOOM TO THE FLAG ON THE CAP UNDERNEATH THE BLACK
WIRE. ATTACH THE CAP TO THE GEARBOX END PLATE USING M8 NUT AND SHAKEPROOF
WASHER ENSURE THAT THE SLEEVING IS PUSHED AS FAR AWAY FROM THE GREEN CONNECTOR
AS POSSIBLE