Possible Printer Problems (continued)
Symptom

Understanding Diagnostic Information

6820 Series 80-Column Printer User Manual
Test or Cause
Cause: printhead gap adjuster
too tight.
Cause: Paper scraps found in
printer mechanism or around
platen.
Printer mechanism unlatched
(unlocked). (portable, fixed
mount printers).
Diagnostic information is stored in flash to support the hardware
configuration, both at time of manufacture and in the field. This
includes recording the initial configuration changes to hardware and
software, and various environmental statistics helpful in determining
why failures are occurring in the field. The flash is provided for
storage of critical data that must remain in the unit after power to the
unit is lost. The data in the flash is used for diagnostic information
for a catastrophic failure, or over the phone with a customer.
Chapter 5 — Troubleshooting and Maintaining the 6820
Solution
Remove ribbon cartridge and turn
knob. If ribbon resists, replace
ribbon cartridge. For help, see
"Installing the Ribbon Cartridge"
on page 11
Replace the mask spring. For help,
see
on page
Set the head gap adjuster to the fifth
notch away from the paper. For
help, see
Gap" on page
If ribbon cartridge bumps against
inside of printer, check white ribbon
cable, home position sensor, and
four screws.
Remove any paper scraps.
Latch (lock) the printer mechanism
into place.
Perform a self-test.
.
"Cleaning the Mask Spring"
103.
"Adjusting the Printhead
12.
91