Hwnetflowman Messages; Hwnetflowman-3; Hwnetflowman-4 - Cisco Catalyst 4500 Series System Message Manual

Cisco ios system message guide ios release 12.2(37)sg
Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

Chapter 2
Messages and Recovery Procedures
Error Message C4K_HWNETFLOWMAN-4-FLOWSLOSTERR: Netflow stats lost due to full hw
flow table.
Explanation
the total collected flow statistics. If the counter that tracks the lost statistics overflowed, an accurate
count of total lost flows is not available.
Recommended Action
Error Message C4K_HWNETFLOWMAN-4-NOFREEFLOWPOLICERS:[dec] flow based policers are in
use. All available flow
policers
Explanation
message is displayed when the user tries to exceed that limit.
Recommended Action
Error Message C4K_HWNETFLOWMAN-4-SWAGEDENTRYHWINVALIDATIONFAILED: Invalidation
failed for Hw flow (index:
Explanation
would indicate that the NetFlow related hardware may have gone bad.
Recommended Action
Error Message C4K_HWNETFLOWMAN-4-NONFATALPARITYERRORINTERRUPTSEEN: Netflow Non
Fatal Parity Error interrupt seen ( [dec] times)
Explanation
The system should be able to recover from this condition. If this condition reoccurs often, the
NetFlow Services Card is probably bad.
Recommended Action
Error Message C4K_HWNETFLOWMAN-4-SEDISABLEDAFTERDELAY: Se is Disabled After a Small
Delay
Explanation
would indicate that the NetFlow related hardware may have gone bad. Access to the hardware was
disabled.
Recommended Action
OL-13091-01
[char] [dec] packets.
If the cache is full, then some flow statistics are lost. This message informs users about
This is an informational message only. No action is required.
policers are in use. Can't allocate more number of flow
The maximum number of flow policers that can be allocated by the system is 512. This
Free existing flow policers before trying to define new ones.
[object-info] ) associated with sw active-aged flow
Software tried to access NetFlow hardware, but there was no response. Typically this
Contact your technical support representative.
The supervisor engine received a nonfatal parity error from the NetFlow Services Card.
This is an informational message only. No action is required.
Software tried to access NetFlow hardware but there was no response. Typically this
This is an informational message only. No action is required.
Catalyst 4500 Series Switch Cisco IOS System Message Guide

HWNETFLOWMAN Messages

2-41

Advertisement

Table of Contents
loading

Table of Contents