Bosch SMB365 Application Note page 31

Multi sensor, wireless demo-board
Table of Contents

Advertisement

Settings
Measurements
According to customized settings (high signal resolution or low power consumption) it is
possible to choose different sample averaging numbers and update rates. E.g. increasing the
resolution leads to a decreased noise with increased power consumption and contrariwise. This
behavior can be edited by the following:
Open Settings
4.
The following message box appears
5.
Chose sampling average number and update rate according to the text
6.
sampling average number = Number of single values for avg. calculation
o edit by mouse scroll
update rate = time for a new "send data command"
o Minimum update rate 0.5 s
sample rate = update rate / sampling average number
o Minimum sampling rate 0.1 s
o Maximum 2 values per second (2 Hz) possible
Rev. 1.0
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such
copying and passing onto third parties.
.
7211RB11
Application Note
BlueBox Demo-Board for the digital sensors
SMB365 (acceleration) and SMD500 (pressure)
Measurements
Page 31
Bosch Sensortec
AN18002