Sensor Evaluation And Direct Data Export - Bosch SMB365 Application Note

Multi sensor, wireless demo-board
Table of Contents

Advertisement

4.4

Sensor Evaluation and Direct Data Export

Using the BST Sensor Desktop software in combination with the BlueBox demo board, it is
possible to perform a minor sensor evaluation. This includes both the SMD500 pressure and the
SMB365 acceleration sensor simultaneously. For basic evaluation purposes, the software
features a so-called online Direct Data Export in *.txt format via USB or wireless via Bluetooth.
The Direct Data Export is unlimited in time. While exporting the Data, for each tab activated
(Cockpit, Altimeter or Accelerometer) a corresponding header is automatically added to the *.txt
file. This means that only the active tab corresponding data is recorded.
Note: To sample either pressure or acceleration specific signals please use corresponding tab
for increased sampling speed.
How to perform a Direct Data Export:
Open menu "Export Data" from the Sensor Desktop menu bar.
Check "Activated" box
Browse and/or create storage folder
Choose appropriate filename and confirm with "OK"
Rev. 1.0
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such