Kodak i1800 Series Image Processing Manual page 51

Hide thumbs Also See for i1800 Series:
Table of Contents

Advertisement

A-61580 November 2007
• Custom: allows you to manually adjust the Color amount and/or
Color threshold.
NOTE: When setting Sensitivity values, it is suggested that you start
with the Medium option and scan a typical job set. If too
many documents were returned as color/grayscale vs. black
and white, then change to the High option and re-run the job.
If too few documents were returned as color/grayscale vs.
black and white, then change to the Low option and re-run
the job. If none of these options provide the desired result,
select Custom to manually adjust Color amount and/or Color
threshold. Custom also allows access to the Learn mode
which provides a method for the scanner to analyze
documents and recommend settings.
Color amount — the amount of color that needs to be present in a
document before it will be saved as color/grayscale. As the value of
Color amount increases, more color pixels are required. The options
range from 1 to 200.
Color threshold — the color threshold or saturation (i.e., pale blue vs.
dark blue) at which a given color will be included in the color amount
calculation. A higher value indicates that a more intense color is
required. The options range from 0 to 100.
Learn — allows you to calculate your settings based on representative
color documents scanned. Before clicking Learn, place at least 5
representative color documents in the input elevator. The documents
will be scanned and analyzed to determine the recommended color
amount.
NOTE: The Color amount and Color threshold sliders will be updated
automatically. If these values do not provide the desired results
with your job set, you may need to adjust the Color threshold
manually.
3-23

Advertisement

Table of Contents
loading