A p p l i c a t i o n V i e w s
TxInterdigitPau
The time between transmitting DTMF digits.
Enter in steps of 10 msec.
RxMinimumFlashH
The shortest length of time required to be onhook
to be recognized as a flash-hook. This value must
be less than RxMaximumFlashH for flash-hook
to be recognized.
RxMaximumFlashH
The longest length of time required to be onhook
to be recognized as a flash-hook. This value must
be greater than RxMinimumFlashH for flash-
hook to be recognized.
TransparentSign
The received signalling state that represents the
idle state. For E1 ports and T1 ESF ports, these
bits represent the ABCD signalling bits on the
interface. The value X means don't care. For E&M
analog ports, Onhook is assumed for the idle
state. The range is 0000 to 1111.
TransparentRxDi
The time the received signalling state must be
equal to the idle state to disconnect the voice call.
Zero value disables idle state disconnect and
maintains the voice call in the answered state.
Time is entered in minutes.
D e v i c e M a n a g e m e n t
TrsprntSingalin
The received signalling state that represents the
Busyout state. For E1 ports and T1 ESF ports,
these bits represent the ABCD signalling bits on
the interface. For E&M analog ports, Offhook is
assumed for the busyout/alarm state. The range
is 0000 to 1111.
XlateSig0000Fro - XlateSig1111Fro
Translate the signalling information received from
the remote end to a value to be transmitted out
the local port. If the local port is a T1/ESF or E1
port enter the ABCD values, for a T1/SF port,
enter the AB(AB) value. If the local port is an
analog E&M port, enter 0000 for idle (Onhook)
and 1111 for active (Offhook). The range is 0000
to 1111.
XlateSig1000Fro
Translate the signalling information received from
the remote end to a value to be transmitted out
the local port. If the local port is a T1/ESF or E1
port enter the ABCD values, for a T1/SF port,
enter the AB(AB) value. If the local port is an
analog E&M port, enter 0000 for idle (Onhook)
and 1111 for active (Offhook). The range is 0000
to 1111.
XlateSig0100Fro
Translate the signalling information received from
the remote end to a value to be transmitted out
Page 86