A p p l i c a t i o n V i e w s

Codex Proprietary Information

This area of the Node Configuration view displays
the following Codex proprietary information:
Codex Group Facility
The facility used in call packets on Codex 6500
links for passing CODEX PRIVATE facilities other
than Hop Count and DCP facilities between 4.xx
nodes. This should be the same on all nodes in
the network. It only needs to be changed if it
interferes with some other private network
facility.
Codex Proprietary Protocol ID
This value is put in the first byte of the Protocol
Identifier field of the CUD in the Call Request
packets for protocols that have not been assigned
a standardized value by the CCITT.
Link - Max Frame Size
The largest datalink level frame that will ever be
received on any link. On WAN links, this does not
include space that is reserved internally for
trailers.
Hop Count Facility
The facility used in call packets on X.25 links
with the INL option for network routing. This
should be the same in all nodes in the network. It
need only be changed if it interferes with some
other private network facility.
D e v i c e M a n a g e m e n t
DCP Facility Code
This value is used in call request and call accept
packets on X.25 links to carry DCP information at
call setup and reconnection time. The code must
be the same for all nodes in the network. The
default value should be changed only when it
interferes with some other facility. This value
must not be the same as Hop Count Facility.
RouteLanSubaddr
Calls with network address composed of the node
address and this subaddress will be routed to a
LAN connection in this node.
Alarm Selection
Specifies the types of alarms and events that are
reported by the node. Possible values are: none,
low, medium, high, conn (connection events), and
code (alarms from Codex 6000 Statistical
Multiplexer devices).

Node Statistics View

Access:
From the Icon Subviews menu for the
MotNodeMgmtApp Application icon, select Node Statistics.
In addition to providing button access to a
number of subviews, the Node Statistics view
contains the following three defined areas:
Last Occurrences
PVC Connections
Page 72