A p p l i c a t i o n V i e w s
GroupSubaddress
Specifies a port subaddress that is shared by
several Voice ports. Incoming calls with this
subaddress are routed to one of several ports
sharing this subaddress. Another name for the
group of ports with the same Group Subaddress
is Hunt Group.
Billing
This controls whether billing (accounting) records
will be created for calls on this port. Valid values
are: enabled, disabled, and nc.
RxsignallingStat
The amount of time to declare a valid supervisory
signalling state change. The granularity is 10
milliseconds.
T1E1RxIdleOnhoo
The signalling state that represents the idle state.
For E1 ports and T1 ESF ports, these bits
represent the ABCD signalling bits on the
interface. For T1 SF ports these bits represent
ABAB signalling bits. The value X means don't
care. The range is from 0000 to 1111.
T1E1TxIdleOnhoo
The signalling state that represents the idle state.
For E1 ports and T1 ESF ports, these bits
represent the ABCD signalling bits on the
interface. For T1 SF ports these bits represent
D e v i c e M a n a g e m e n t
ABAB signalling bits. The range is from 0000 to
1111.
T1E1RxActiveOff
The signalling state that represents the active
state. For E1 ports and T1 ESF ports, these bits
represent the ABCD signalling bits on the
interface. For T1 SF ports these bits represent
ABAB signalling bits.The value X means don't
care. The range is from 0000 to 1111.
T1E1TxActiveOff
The signalling state that represents the active
state. For E1 ports and T1 ESF ports, these bits
represent the ABCD signalling bits on the
interface. The range is from 0000 to 1111.
T1E1RingingStat
The signalling state that represents the ringing
state. For E1 ports and T1 ESF ports, these bits
represent the ABCD signalling bits on the
interface. For T1 SF ports, these bits represent
ABAB signalling bits.The value X means don't
care. The range is from 0000 to 1111.
T1E1NoRingingSt
The signalling state that represents the no ringing
state. For E1 ports and T1 ESF ports, these bits
represent the ABCD signalling bits on the
interface. For T1 SF ports these bits represent