Ioxadm - Fujitsu SPARC Enterprise M3000 Xscf Reference Manual

Xscf control package (xcp) 109x
Hide thumbs Also See for SPARC Enterprise M3000:
Table of Contents

Advertisement

NAME
ioxadm - manage External I/O Expansion Units
SYNOPSIS
ioxadm [-f] [-p] [-v] [-M] env [-e] [-l] [-t] [ target [ sensors]]
ioxadm [-f] [-p] [-v] [-M] list [ target]
ioxadm [-f] [-p] [-v] [-M] locator [on|off] [ target]
ioxadm [-f] [-p] [-v] [-M] poweroff target
ioxadm [-f] [-p] [-v] [-M] poweron target
ioxadm [-f] [-p] [-v] [-M] reset target
ioxadm [-f] [-p] [-v] [-M] setled [ on|off|slow|fast] target led_type
ioxadm -h
DESCRIPTION
ioxadm(8) manages External I/O Expansion Units and link cards attached to the
system.
The ioxadm(8) command is not available on the M3000 server.
For this utility, an operand with parameters and a target device must both be
specified. The target device can be a downlink card mounted in a built-in PCI slot
in the host system; an External I/O Expansion Unit; or a field replaceable unit
(FRU) in an External I/O Expansion Unit. The downlink card is identified by a
string which identifies the host path to the card. An uplink card is an FRU in the
I/O boat.
You must have one of the following privileges to run these commands:
Privileges
Required Privileges
platop
platadm
fieldeng
Refer to setprivileges(8) for more information.
Operands
env, list
env, list, locator, poweroff, poweron
All operands
System Administration

ioxadm(8)

79

Advertisement

Table of Contents
loading

Table of Contents